OHSU Laboratory Services test LAB103756, CPT 86780. Specimen: 4.0 mL blood in serum separator tube (SST). Send 2 mL serum aliquot.. Turnaround: Routine: 2 days, additional time for reflex testing..

Syphilis Screen w/Reflex (Treponemal Ab-First, Reverse Algorithm) is OHSU Laboratory Services test code LAB103756, billed with CPT 86780. Specimen: 4.0 mL blood in serum separator tube (SST). Send 2 mL serum aliquot.. Turnaround time: Routine: 2 days, additional time for reflex testing.. Performing laboratory: OHSU Laboratory Services, CLIA 38D0676694 (Portland, OR). Other labs in the directory with tests billed under the same CPT: Quest Diagnostics, Michigan Medicine Laboratories (MLabs), Labcorp, ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryOHSU Laboratory Services
CLIA number38D0676694
Test codeLAB103756
CPT86780 x 1
LOINC—
Specimen4.0 mL blood in serum separator tube (SST). Send 2 mL serum aliquot. Minimum volume is 1.5 mL serum. Storage/Transport Temperature: Refrigerated. Remove specimen from clot or separator gel prior to storage. Stabile refrigerated (2 to 8 C) for 5 days. Stable frozen -20 C or colder for 8 to 30 days.
Turnaround timeRoutine: 2 days, additional time for reflex testing.

Test includes

Treponema Pallidum Antibody. If reactive, reflex to RPR w/reflex to titer or TP-PA. Additional charges will apply.

Reference range

Treponema pallidum Antibodies: Nonreactive RPR: Nonreactive RPR Titer: Less than 1:1

Special instructions

Methodology: Chemiluminescent Microparticle Immunoassay (CMIA) Recommended test for Syphilis Screening for Sexually Transmitted Infection (STI) and pregnancy. For patients younger than 18 months, refer to syphilis Screen w/'Reflex (RPR AB-First, Tradition Algorithm) (LAB00282). T.Pallidum AB By TP-PA is sent to ARUP for testing. ARUP Test Directory: Treponema pallidum Antibody by TP-PA (Opens in a new window)

Section

Immunology

Performed

5 days a week.

Pediatric specimen

*Do not order for patients less than 18 months. See comments below.* 4.0 mL blood in serum separator tube (SST). Send 2 mL serum aliquot. Minimum volume is 1.5 mL serum. Storage/Transport Temperature: Refrigerated. Remove specimen from clot or separator gel prior to storage. Stabile refrigerated (2 to 8 C) for 5 days. Stable frozen -20 C or colder for 8 to 30 days.

View this test on OHSU Laboratory Services's website → · Last checked 2026-11-29

Other tests billed with CPT 86780

Search the National Lab Test Directory · All OHSU Laboratory Services tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation