Michigan Medicine Laboratories (MLabs) test SYPH, CPT 86780. Specimen: 1.0 ml. Turnaround: 24 hours.

Syphilis Screening, Total Antibodies with Reflex to RPR and TPPA (Reverse Algorithm) is Michigan Medicine Laboratories (MLabs) test code SYPH, billed with CPT 86780. Specimen: 1.0 ml. Turnaround time: 24 hours. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Labcorp, ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeSYPH
CPT86780
LOINC—
Specimen1.0 ml
Volume1.0 ml
Turnaround time24 hours
Storage / transportRoom temperature (25C) up to 3 days; refrigerated (2-8C) up to 7 days. Longer storage, keep at -20C or colder

Use

Syphilis reverse algorithm is used to screen patients for syphilis. Positive or equivocal result will reflex to RPR and TPPA, if indicated to help differentiate between active infection, past infection, no infection or false positive total antibody. All results must be reviewed before making a clinical decision.

Collection instructions

Collect SST and send refrigerated to main hospital specimen processing

Reference range

Nonreactive

Limitations

A nonreactive result does not exclude the possibility of exposure to or infection with T. pallidum. Antibodies may be at low or undetectable levels in incubating or early primary disease and in some clinical conditions. Detection of treponemal antibodies may indicate recent, past or successfully treated syphilis infections and therefore cannot be used to differentiate between active and cured cases. A patient with a Syphilis Total reactive result will usually remain reactive for life, and therefore, antibody indices cannot be used to determine responses to therapy. In these cases, an RPR should be used to monitor the patient.

Section

Immunology

Performed

M-F

Contraindications

Contaminated, icteric, lipemic, hemolyzed or heat inactivated sera my cause erroneous results and should be avoided.

NY State approved

No

Alternate specimens

red top, EDTA or heparin

Performing Laboratory

Immunology & Special Chemistry

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 86780

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation