Zika Virus MAC-ELISA, IgM, Serum (Mayo): Michigan Medicine Laboratories (MLabs) test VZIKM

Michigan Medicine Laboratories (MLabs) test VZIKM, CPT 86794. Specimen: 1 mL serum. Turnaround: 2 - 15 days.

Zika Virus MAC-ELISA, IgM, Serum (Mayo) is Michigan Medicine Laboratories (MLabs) test code VZIKM, billed with CPT 86794. Specimen: 1 mL serum. Turnaround time: 2 - 15 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Labcorp, Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeVZIKM
CPT86794
LOINC—
Specimen1 mL serum
Volume1 mL serum
Turnaround time2 - 15 days
Storage / transportStrict frozen

Use

Screening for the presence of IgM-class antibodies to Zika virus in patients presenting with symptoms for 14 or more days. Establishment of baseline serologic levels of IgM-class antibodies to Zika virus in women who have traveled to a Zika virus endemic region or who have had sexual exposure to Zika virus and who are considering conception.

Collection instructions

Collect specimen in SST or red top tube. Centrifuge, aliquot serum into a plastic screw capped vial, and freeze.

Reference range

Negative

Limitations

This assay is a screening test for IgM-class antibodies to Zika virus. A presumptive positive result by this assay is not diagnostic for Zika virus infection and requires confirmatory testing by plaque reduction neutralization testing (PRNT) performed at the CDC or a CDC-designated laboratory. Confirmatory testing by a molecular assay for detection of Zika virus RNA may also be considered. This assay should be used in patients presenting at least 2 weeks postsymptom onset or last possible exposure to Zika virus. Reverse transcription-polymerase chain reaction (RT-PCR) for Zika virus RNA detection should be ordered in patients with less than 2 weeks of symptoms or postexposure. A single…

Section

Sendout Testing

Performed

Bimonthly on the first and third Wednesday

Contraindications

This test is used for screening for the presence of IgM-class antibodies to Zika virus; this test is not intended for medical-legal use or for asymptomatic couples attempting conception.

NY State approved

No

Performing Laboratory

Sendout Testing

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 86794

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation