Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Respiratory Pathogen Panel + SARS-CoV-2 by PCR

Respiratory Pathogen Panel + SARS-CoV-2 by PCR: Michigan Medicine Laboratories (MLabs) test RPANC or ERPNC

Michigan Medicine Laboratories (MLabs) test RPANC or ERPNC, CPT 0202U. Specimen: 1 nasopharyngeal swab in UTM / VTM; M2 mL BAL; 2 mL tracheal aspirate or suction; 2 mL nasal aspirate. Turnaround: 1 day (6 hours for UM inpatients and ED)..

Respiratory Pathogen Panel + SARS-CoV-2 by PCR is Michigan Medicine Laboratories (MLabs) test code RPANC or ERPNC, billed with CPT 0202U. Specimen: 1 nasopharyngeal swab in UTM / VTM; M2 mL BAL; 2 mL tracheal aspirate or suction; 2 mL nasal aspirate. Turnaround time: 1 day (6 hours for UM inpatients and ED).. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Allina Health Laboratory (Abbott Northwestern), OHSU Laboratory Services, Labcorp.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeRPANC or ERPNC
CPT0202U
LOINC—
Specimen1 nasopharyngeal swab in UTM / VTM; M2 mL BAL; 2 mL tracheal aspirate or suction; 2 mL nasal aspirate
Volume1 nasopharyngeal swab in UTM / VTM; M2 mL BAL; 2 mL tracheal aspirate or suction; 2 mL nasal aspirate
Turnaround time1 day (6 hours for UM inpatients and ED). Testing is performed 24/7 throughout the day with turnaround time dependent on staffing and the current load on the instrument. Non- Nasopharyngeal specimens - 12 hour turn around time
Storage / transportSpecimens in VTM should be processed and tested as soon as possible. If storage is required, specimens in VTM can be held at room temperature (15°-25°C) for up to 4 hours, at refrigerator temperature (2°-8° C) for up to 3 days, or at freezer temperature (<-15° C or greater than or equal to -70 C°) for up to 30 days.

Also known as: Metapneumovirus; Adenovirus; Respiratory Syncytial Virus; Parainfluenza; Influenza; Mycoplasma pneumoniae; Bordetella pertussis; Bordetella parapertussis

Use

The BIOFIRE Respiratory Panel 2.1 (RP2.1) is a PCR-based multiplexed nucleic acid test intended for the simultaneous qualitative detection and identification of multiple respiratory viral and bacterial nucleic acids in nasopharyngeal swabs (NPS) obtained from individuals suspected of respiratory tract infections, including COVID-19. Respiratory pathogens cause acute local and systemic disease, with the most severe cases occurring in children, the elderly, and immunocompromised individuals. Respiratory symptoms can include coughing, nasal discharge, congestion, fever, wheezing, shortness of breath, headache, and myalgia. Due to the similarity of diseases caused by many viruses and bacteria,…

Reference range

Not detected

Limitations

If four or more organisms are detected in a specimen, retesting is recommended to confirm the polymicrobial result. The performance of this test has not been established for patients without signs and symptoms of respiratory infection. The performance of the RP2.1 has not been established for monitoring treatment of any infection with any of the panel organisms. There is a risk of false positive or false negative values resulting from improperly collected, transported, or handled specimens. Negative results should not be used as the sole basis for diagnosis, treatment, or other management decisions. Positive and negative predictive values are highly dependent on prevalence. False negative…

Section

Molecular Microbiology

Performed

Daily

NY State approved

No

Performing Laboratory

Microbiology

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 0202U

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation