Respiratory Pathogen Panel With SARS-CoV-2, NAA: Labcorp test 139845
Labcorp test 139845, CPT 0202U. Specimen: Nasopharyngeal swab. Turnaround: 2 - 4 days.
Also known as: BioFire; FilmArray
Test includes
Adenovirus; Bordetella pertussis ; Bordetella parapertussis : Chlamydophila pneumoniae ; SARS-CoV-2; coronavirus 229E; coronavirus HKU1; coronavirus NL63; coronavirus OC43; human metapneumovirus; human rhinovirus/enterovirus; influenza A; influenza A subtype H1; influenza A subtype H3; influenza A subtype H1-2009; influenza B; Mycoplasma pneumoniae ; parainfluenza virus 1; parainfluenza virus 2; parainfluenza virus 3; parainfluenza virus 4; respiratory syncytial virus
Use
This test provides simultaneous qualitative detection and identification of multiple respiratory viral and bacterial nucleic acids in nasopharyngeal swabs obtained from individuals suspected of respiratory tract infections. Note: Labcorp also offers smaller targeted panels for Influenza, RSV and SARS-CoV-2 (see test numbers 140140, 140147 or 140163).
Methodology
Nucleic acid amplification (polymerase chain reaction (PCR))
Collection instructions
Collect NP swab per standard techniques and immediately place swab in up to 3 mL of viral transport media.
Stability
| Temperature | Period |
|---|---|
| Room temperature | 4 hours (stability provided by manufacturer or literature reference) |
| Refrigerated | 3 days (stability provided by manufacturer or literature reference) |
| Frozen | 30 days at 15°C or below (stability provided by manufacturer or literature reference) |
Causes for rejection
Improper collection; inadequate specimen; improper labeling; specimen leaked in transit; quantity not sufficient for analysis; name discrepancies; specimen exceeding storage requirements; nasal swabs or any other upper respiratory sample other than nasopharyngeal swab in viral transport media
Limitations
The performance of this test has not been established for patients without signs and symptoms of respiratory infection. Results from this test must be correlated with the clinical history, epidemiological data, and other data available to the clinician evaluating the patient. Viral and bacterial nucleic acids may persist in vivo independent of organism viability. Detection of organism target(s) does not imply that the corresponding organisms are infectious or are the causative agents for clinical symptoms. The detection of viral and bacterial nucleic acid is dependent upon proper specimen collection, handling, transportation, storage and preparation. Failure to observe proper procedures in…
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 139592 | Adenovirus | 82160-3 | |
| 139593 | Coronavirus HKU1 | 82161-1 | |
| 139594 | Coronavirus NL63 | 82162-9 | |
| 139597 | Coronavirus 229E | 82163-7 | |
| 139601 | Coronavirus OC43 | 82164-5 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 0202U
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.