Respiratory Viruses by PCR (Influenza & RSV): Michigan Medicine Laboratories (MLabs) test PCRSC (NCRC) & ERSC (UH)
Michigan Medicine Laboratories (MLabs) test PCRSC (NCRC) & ERSC (UH), CPT 87631. Specimen: 1 Viral transport media (BD UVT, Copan UTM or equivalent). Turnaround: 1 day (6 hours for UM Inpatient and ED).
Also known as: Respiratory viruses Screen; RSV by PCR; Influenza Virus (A, B) by PCR; Influenza B by PCR; Respiratory Syncytial Virus by PCR; Influenza A by PCR; Viral Respiratory Screen; Influenza Virus (A, B) by PCR; Swine Flu (H1N1) Screen
Use
The DiaSorin Molecular Simplexa™ Flu A/B & RSV Direct Gen II assay is intended for use on the LIAISON® MDX instrument for the in vitro qualitative detection and differentiation of influenza A virus, influenza B virus, and respiratory syncytial virus (RSV) RNA in nasopharyngeal swabs (primarily) from human patients with signs and symptoms of respiratory tract infection in conjunction with clinical and epidemiological risk factors. This test is intended for use as an aid in the differential diagnosis of influenza A, influenza B, and RSV viral infections in humans. If infection with a novel influenza A virus is suspected based on current clinical and epidemiological screening criteria…
Collection instructions
With the patient's head stabilized, gently insert the flocked swab horizontally along the floor of the nasal passage (parallel to the palate), directed toward the posterior nasopharynx. Do not angle the swab superiorly toward the cribriform plate. Advance the swab until resistance is met at the posterior nasopharyngeal wall (typically 5–7 cm in adults; proportionally less in children). The swab should reach a depth approximately equal to the distance from the nostril to the tragus of the ear. Rotate the swab gently 2–3 times against the posterior nasopharyngeal mucosa, maintaining firm but gentle contact. Leave in place for 5–10 seconds to allow adequate specimen absorption. Withdraw the swab slowly and steadily while continuing to rotate. Avoid contact with the anterior nares, nasal hairs, or facial skin on removal. Immediately place the swab into the labeled viral transport media (VTM) tube. Break or cut the swab shaft at the score line and discard the upper portion. Secure the cap tightly. Transport on ice and deliver to the laboratory as soon as possible.
Reference range
Negative
Limitations
A negative test does not rule out infection. The specimen must be taken at the appropriate time during infection and properly stored and transported; if optimum conditions are not met, the viral agents may not be detected in the presence of an infection.
Section
Molecular Microbiology
Performed
Daily
NY State approved
No
Performing Laboratory
Microbiology
View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29
Other tests billed with CPT 87631
- Influenza A, Influenza B and Respiratory Syncytial Virus, NAA
- Parainfluenza 1-4 by PCR
- Respiratory Virus Mini Panel by PCR
- Respiratory Viruses DFA with Reflex to Respiratory Virus Mini Panel by PCR
Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations