Influenza A, Influenza B and Respiratory Syncytial Virus, NAA: Labcorp test 140163
Labcorp test 140163, CPT 87631. Specimen: Nasal swab; nasopharyngeal swab. Turnaround: 2 - 4 days.
Use
Detection of Influenza A, Influenza B, and Respiratory Syncytial Virus (RSV) to assist in the diagnosis of viral respiratory infections.
Methodology
Nucleic Acid Amplification (NAA)
Collection instructions
For swabs in viral transport medium: Oropharyngeal (OP) samples: Swab included in viral transport medium is acceptable for submission. Nasopharyngeal (NP) samples: Use separate NP swab submitted in viral transport medium (discard OP swab included with viral transport medium). Exact manufacturer of the swab and transport medium may vary with supply. Any swab of appropriate size and configuration with a synthetic tip can be used except for calcium alginate tips, swabs with preservatives, and swabs with wood shafts. Viral transport medium acceptable for collection of influenza specimens in 1 mL or 3 mL volumes can be used to transport swabs for COVID-19 testing. For swabs in saline: OP, NP or anterior nasal swabs may be placed in 1 to 3 mL of sterile saline (0.85 to 0.9%) in a sterile screw cap container. Do not use vacutainer or "pop-top" tubes. Any swab of appropriate size and configuration with a cotton or synthetic tip can be used except for calcium alginate tips, swabs in preservatives, and swabs with wood shafts.
Stability
| Temperature | Period |
|---|---|
| Room temperature | 24 hours |
| Refrigerated | 72 hours |
| Frozen | -20° C, no limit |
Causes for rejection
Vacutainers and other "pop-top" tubes; bronchoalveolar lavage; bronchial wash; cotton-tip swabs in UTM/VTM; swabs in calcium alginate; ESwab™; swabs with wooden shafts; refrigerated samples greater than 72 hours old; room temperature samples greater than 24 hours old; improperly labeled, grossly contaminated, broken or leaking transport device; collection with substances inhibitory to PCR including heparin, hemoglobin, ethanol, EDTA concentrations >0.01M; specimens submitted in glass tubes/containers; dry swab without media; swabs in "molecular media" (such as PrimerStore MTM or other guanidine-containing media); Aptima swabs; swabs in gel-based, anaerobic, or charcoal media; 3D printed swabs; or Hanks' balanced salt solution
Special instructions
Please note: Labcorp does not currently collect specimens for this test. Patients for whom testing has been ordered should not be sent to a Labcorp location to have a specimen collected. Instead, an appropriate specimen should be collected at the health care facility where the patient was seen and the test was ordered. The specimen should be sent to Labcorp using standard procedures. Please note: It takes approximately 2 - 4 days from the date of pickup of a specimen for testing to the release of the test result to the health care provider. Test results are most typically reported electronically, which generally allows for faster delivery. This time frame can vary based on demand, the length of time to transport the specimen to Labcorp's test facilities, and the prioritization of the patients (as defined by heath care authorities and the White House Coronavirus Task Force, HHS and other health authorities). Labcorp is working continuously to support the needs of health care workers, patients, government, clients and other organizations, and expects capacity to continue to increase.
Limitations
This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 140144 | RSV, NAA | 76089-2 | |
| 140142 | Influenza A, NAA | 76078-5 | |
| 140143 | Influenza B, NAA | 76080-1 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 87631
- Parainfluenza 1-4 by PCR
- Respiratory Virus Mini Panel by PCR
- Respiratory Viruses DFA with Reflex to Respiratory Virus Mini Panel by PCR
Search the National Lab Test Directory · All Labcorp tests and CLIA locations