Point of Care- SARS-CoV-2 (COVID-19)/ Influenza (A,B)/ RSV by PCR, GeneXpert: Michigan Medicine Laboratories (MLabs) test P4PLX
Michigan Medicine Laboratories (MLabs) test P4PLX, CPT 87637. Turnaround: Approximately; 30 minutes for positive results, and 30-50 mi.
Use
The Cepheid Xpert Xpress SARS-CoV-2/Flu/RSV plus assay is a rapid, real-time RT-PCR test intended for the simultaneous qualitative detection and differentiation of SARS-CoV-2, influenza A, influenza B, and respiratory syncytial virus (RSV) viral DNA in either nasopharyngeal swab, nasal swab or nasal wash/aspirate specimens collected from individuals suspected of respiratory viral infection consistent with COVID-19 by their healthcare provider. The Cepheid Xpert Xpress SARS-CoV-2/Flu/RSV assay is only for use under the Food and Drug Administration’s Emergency Use Authorization. Fact Sheet for Healthcare Providers: " https://www.fda.gov/media/136313/download " Fact Sheet for Patients:"…
Collection instructions
Gently insert mini-tipped flocked nasopharyngeal swab (swab on flexible plastic shaft) through the nostril and into the nasopharynx, reaching the posterior nasopharynx. Gently rotate swab, then remove, and break swab off into tube of transport media. Make sure the swab is fully immersed in the transport media, and that the shaft is short enough to completely tighten the cap. For best results testing should be performed immediately after collection. Obtaining columnar epithelial cells will enhance reliability of viral detection. Please see CDC for current sample collection guidance: https://www.cdc.gov/coronavirus/2019-nCoV/lab/guidelines-clinical-speci… .
Reference range
Not Detected for influenza A, influenza B, respiratory syncytial virus, and SARS-CoV-2
Limitations
1.Performance of the Xpert SARS-CoV-2 has only been established in nasopharyngeal swab specimens. Specimen types other than nasopharyngeal swab may give inaccurate results. A false negative result may occur if a specimen is improperly collected, transported, handled. 2. A false negative result may occur if a specimen is improperly collected, transported, or handled. False negative results may also occur if inadequate numbers of organisms are present in specimen. 3. As with any molecular test, mutations within the target regions of the Xpert Xpress SARS-CoV-2, influenza A, influenza B, and respiratory syncytial virus could affect primer and/or probe binding resulting in failure to detect the…
Section
Point-of-Care Testing
Performed
Performed during normal operational hours of the designated POC testing areas.
NY State approved
No
Performing Laboratory
Point-of-Care Testing
View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29
Other tests billed with CPT 87637
- 2019 Novel Coronavirus (COVID-19) With Influenza A, Influenza B and Respiratory Syncytial Virus, NAA
- COVID & Influenza A/B & RSV PCR, Routine
- SARS-CoV-2 (COVID-19), Flu A+B, and RSV
Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation