SARS-CoV-2 (COVID-19), Flu A+B, and RSV: Michigan Medicine Laboratories (MLabs) test COFLR
Michigan Medicine Laboratories (MLabs) test COFLR, CPT 87637. Turnaround: 6 - 18 hours from receipt in lab.
Use
The Alinity m Resp-4-Plex is a multiplexed, real-time in vitro reverse transcription polymerase chain reaction (RT-PCR) assay for use with the automated Alinity m System for the qualitative detection and differentiation of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), influenza A virus, influenza B virus, and Respiratory Syncytial Virus (RSV) in nasopharyngeal swab specimens collected from patients with signs and symptoms of respiratory tract infection. Clinical signs and symptoms of respiratory tract infection due to SARS-CoV-2, influenza A, influenza B, and RSV can be similar. The Alinity m Resp-4-Plex assay is intended for use in the differential detection of SARS-CoV-2,…
Collection instructions
Nasopharyngeal specimen collection: With the head in a tilted position, insert the swab into one nostril, advancing into the nasopharynx until resistance is felt. Rotate the swab several times on the nasopharyngeal membrane to allow adequate collection of epithelial cells - a minimum of 3 "full twists" is standard to obtain a good collection; if unsure you maintained contact with the membrane, add another 1-2 full twists. Insert swab into viral transport media, break off swab stick at the breakpoint to ensure it will fully fit into the closed tube. Fasten the cap tightly to prevent leakage. Send to the laboratory as soon as possible. Obtaining columnar epithelial cells will enhance reliability of viral detection.
Reference range
Not detected
Limitations
This test is not intended to detect influenza C virus infections. Positive results are an indication of the presence of the identified virus, but do not rule out bacterial infection or co-infection with other pathogens not detected by the test. The agent(s) detected by the Alinity m Resp-4-Plex assay may not be the definite cause of disease. Negative results do not preclude SARS-CoV-2, influenza A, influenza B, or RSV infections and should not be used as the sole basis for diagnosis, treatment or other patient management decisions. Recent patient exposure to FluMist or other attenuated influenza vaccines may cause inaccurate positive results for flu A and flu B due to the presence of…
Section
Molecular Microbiology
Performed
Daily
NY State approved
No
Performing Laboratory
Microbiology
View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29
Other tests billed with CPT 87637
- 2019 Novel Coronavirus (COVID-19) With Influenza A, Influenza B and Respiratory Syncytial Virus, NAA
- COVID & Influenza A/B & RSV PCR, Routine
- Point of Care- SARS-CoV-2 (COVID-19)/ Influenza (A,B)/ RSV by PCR, GeneXpert
Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation