Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › MDM2 Amplification by FISH

MDM2 Amplification by FISH: Michigan Medicine Laboratories (MLabs) test MMDM2

Michigan Medicine Laboratories (MLabs) test MMDM2, CPT 88377. Specimen: Formalin-fixed, paraffin-embedded tissue. Turnaround: 3 - 10 days.

MDM2 Amplification by FISH is Michigan Medicine Laboratories (MLabs) test code MMDM2, billed with CPT 88377. Specimen: Formalin-fixed, paraffin-embedded tissue. Turnaround time: 3 - 10 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Allina Health Laboratory (Abbott Northwestern), Labcorp, Cleveland Clinic Laboratories.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeMMDM2
CPT88377-TC
LOINC—
SpecimenFormalin-fixed, paraffin-embedded tissue
VolumeFormalin-fixed, paraffin-embedded tissue
Turnaround time3 - 10 days

Also known as: 12q15; Chromosome 12 centromere (CEP12); Liposarcoma

Use

This test detects amplification of the MDM2 gene region (12q15) via fluorescence in situ hybridization (FISH) in formalin-fixed, paraffin-embedded tissue specimens. FISH is performed using Vysis (Abbott Molecular, Inc.) probes to the MDM2 locus (12q15) and the chromosome 12 centromere (CEP12). MDM2 amplification is present in most cases of atypical lipomatous tumor/well-differentiated liposarcoma and most cases of dedifferentiated liposarcoma. MDM2 amplification is not seen in benign lipomatous tumors. Testing for MDM2 amplification may aid in the diagnosis and classification of these tumors.

Collection instructions

A formalin-fixed, paraffin-embedded tissue block containing sufficient neoplastic cells is preferred. Unstained slides (3, 4-micron slides) with associated H&E stained slide are also acceptable. Decalcified tissue or other fixatives will be accepted and the assay attempted, however these may result in failed testing due to degraded nucleic acid. Both blocks and slides should be stored at room temperature.

Reference range

Interpretive report provided.

Limitations

Amplification may not be detected if sufficient liposarcomatous tissue is not present within the submitted block. Selection of the appropriate block may be problematic given the histologic similarity between atypical lipomatous tumor/well-differentiated liposarcoma and adjacent benign adipose tissue.

Section

Cytogenetics

Performed

Monday - Thursday

NY State approved

No

Performing Laboratory

Cytogenetics

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 88377

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation