Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Cytogenetics, FISH for Melanoma, Multiplex Probe, FFPE

Cytogenetics, FISH for Melanoma, Multiplex Probe, FFPE: Michigan Medicine Laboratories (MLabs) test CGDMP

Michigan Medicine Laboratories (MLabs) test CGDMP, CPT 88377. Turnaround: 10-14 days.

Cytogenetics, FISH for Melanoma, Multiplex Probe, FFPE is Michigan Medicine Laboratories (MLabs) test code CGDMP, billed with CPT 88377. Turnaround time: 10-14 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Labcorp, Cleveland Clinic Laboratories.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeCGDMP
CPT88377-TC
LOINC—
Turnaround time10-14 days

Also known as: FISH for 8q24 (MYC); FISH panel 9q21 (CDKN2A) and CEP9; FISH panel 6p25 (RREB1), 6q23 (MYB), 11q13 (CCND1) and CEP6; Multiplex FISH for Melanoma

Use

This test is designed to detect copy number abnormalities at probed loci via fluorescence in situ hybridization (FISH) in FFPE tissue specimens. The test is used to aid in the diagnosis of histologically ambiguous melanocytic lesions; a positive result favors a diagnosis of melanoma while a negative result one of nevus. Published data report a sensitivity of 86-100% and a specificity of 76-98% for the diagnosis of melanoma in selected cohorts including atypical spitzoid neoplasms. Three multiprobe FISH panels are available. Panel 1 include probes 6p25 (RREB1), 6q23 (MYB), 11q13 (CCND1) and CEP6; panel 2 include 9q21 (CDKN2A) and CEP9; panel 3 include 8q24 (MYC). Panel 1 is recommended for…

Collection instructions

Submit a formalin-fixed, paraffin-embedded (FFPE) block containing tumor tissue (preferred specimen). If a block is not available submit 3 FFPE unstained sections at 4-micron thickness placed on electrostatic-coated slides, unbaked and one regular H&E obtained as serial sections; store at room temperature.

Reference range

Interpretive report provided.

Limitations

This test detects copy number aberrations on specific chromosomal targets (6p25, 6q23, 11q13, 9p21, and 8q24), which are documented to have frequent association with melanoma; however, it will not identify potentially significant aberrations in non-targeted chromosomal segments. A false positive result can occur in the setting of tetraploidy.

Section

Cytogenetics

Performed

Monday - Friday, 8:30 am - 4:30 pm

NY State approved

No

Performing Laboratory

Cytogenetics

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 88377

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation