Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Hexagonal Phospholipid Neutralization

Hexagonal Phospholipid Neutralization: Michigan Medicine Laboratories (MLabs) test HEXAG

Michigan Medicine Laboratories (MLabs) test HEXAG, CPT 85598. Specimen: Full 2.7mL tube or 1mL plasma aliquot. Turnaround: 2 hours.

Hexagonal Phospholipid Neutralization is Michigan Medicine Laboratories (MLabs) test code HEXAG, billed with CPT 85598. Specimen: Full 2.7mL tube or 1mL plasma aliquot. Turnaround time: 2 hours. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Labcorp, Cleveland Clinic Laboratories.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeHEXAG
CPT85598
LOINC—
SpecimenFull 2.7mL tube or 1mL plasma aliquot
VolumeFull 2.7mL tube or 1mL plasma aliquot
Turnaround time2 hours
Storage / transportRoom temperature for whole blood or frozen aliquot of citrated plasma

Also known as: Staclot LA; Lupus Anticoagulant; Hexagonal LA; Phospholipid Antibody (Lupus Anticoagulant)

Use

Detection of phospholipid antibody (lupus anticoagulant) in plasma.

Collection instructions

Collect specimen in a blue top (citrate 3.2%) tube. Mix by inversion. Specimen should arrive at lab within 3 hours of collection; transport at room temperature. Alternatively, centrifuge, aliquot plasma into a plastic tube, and freeze the specimen within 4 hours of collection. Transport frozen specimen on dry ice. Collection of the blood through lines that have been previously flushed with heparin should be avoided. If the blood must be drawn through a VAD (vascular access device), the line should be flushed with 5 mL of saline and the first 5 mL of blood or six dead space volumes of the VAD discarded.

Reference range

Negative or <= 8.2

Section

Coagulation

Performed

Monday and Thursday

Contraindications

Plasma containing heparin levels greater than 1.0 IU/ml may give false positive results and should not be tested. This test is non-diagnostic in the setting of Low-molecular-weight heparin/ unfractionated heparin/direct oral anticoagulant use. This test is not indicated for inpatient evaluation of acute thrombosis.

NY State approved

No

Performing Laboratory

Clinical Core Laboratory

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 85598

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation