Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Hexagonal Phase Phospholipid (HPP)

Hexagonal Phase Phospholipid (HPP): Labcorp test 117838

Labcorp test 117838, CPT 85598. Specimen: Plasma, frozen. Turnaround: 2 - 3 days.

Hexagonal Phase Phospholipid (HPP) is Labcorp test code 117838, billed with CPT 85598. Specimen: Plasma, frozen. Turnaround time: 2 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code117838
CPT85598
LOINC3282-1
SpecimenPlasma, frozen
Volume1 mL
ContainerBlue-top (sodium citrate) tube
Turnaround time2 - 3 days
Storage / transportFreeze.

Also known as: Neutralization, Hexagonal Phase Phospholipid

Use

This test system is designed for the qualitative detection of lupus anticoagulants in plasma.

Methodology

Clotting time using an activated partial thromboplastin time (aPTT) reagent is determined both in the presence and in the absence of HPP. The assay is considered to be positive for lupus anticoagulant when addition of HPP reduces the aPTT by more than the laboratory defined cutoff.

Collection instructions

Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove / 3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Patient preparation

Ideally, the patient should not be on anticoagulant therapy. Avoid warfarin (Coumadin®) therapy for two weeks prior to the test and heparin, direct Xa, and thrombin inhibitor therapies for about three days prior to testing. Do not draw from an arm with a heparin lock or heparinized catheter.

Causes for rejection

Severe hemolysis; improper labeling; clotted specimen; specimen diluted with IV fluids; samples thawed in transit; improper sample type; sample out of stability

Reference range

0–8 sec Patients with a prolonged aPTT or lupus sensitive aPTT screening test: • Reduction of the aPTT result by more than a laboratory-determined cutoff (test result that is elevated) as the result of adding hexagonal phase phospholipid (HPP) is consistent with the presence of a phospholipid-dependent inhibitor (lupus anticoagulant). • Failure of the HPP to reduce the aPTT result (test result that falls in the normal reference interval) can be interpreted as a possible indication of the presence of one or more specific factor inhibitors.

Special instructions

If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.

Limitations

It should be noted that current guidelines from the International Society on Thrombosis and Haemostasis (ISTH) recommend that at least two screening tests based on different physical or chemical principles be used for lupus anticoagulant (LA) testing. This is because LA is a diverse group of antibodies, and no single test is sensitive enough to detect all types. A negative result by a single testing modality does not completely exclude the presence of a lupus anticoagulant. Refer to Lupus Anticoagulant With Reflex [117892] for more details regarding the limitations of lupus anticoagulant testing.

LOINC map

Result codeResult nameUnitsResult LOINC
117839Hexagonal Phase Phospholipidsec3282-1

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85598

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation