Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Microarray-Products of Conception (POC) Reveal® FFPE

Microarray-Products of Conception (POC) Reveal® FFPE (Women's Health): Labcorp test 511997

Labcorp test 511997, CPT 81229. Specimen: Preferred fixed products of conception (POC), formalin-fixed paraffin-embedded (FFPE) tissue. Turnaround: 14 - 21 days.

Microarray-Products of Conception (POC) Reveal® FFPE is Labcorp test code 511997, billed with CPT 81229. Specimen: Preferred fixed products of conception (POC), formalin-fixed paraffin-embedded (FFPE) tissue. Turnaround time: 14 - 21 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code511997 (Women's Health)
CPT81229
LOINC48002-0, 62357-9, 62377-7, 94087-4
SpecimenPreferred fixed products of conception (POC), formalin-fixed paraffin-embedded (FFPE) tissue
VolumeOne paraffin block or ten 10-micron thick section slides
Minimum volumeTen 10-micron thick section slides
ContainerParaffin block transport pouch
Turnaround time14 - 21 days
Storage / transportRoom temperature

Also known as: aCGH; CGH; CMA; Microarray; Reveal® SNP Microarray-Products of Conception (POC); SNP Array; WGA

Use

This test will detect chromosomal imbalance that could be associated with developmental delay/congenital anomalies. It provides detection of possible uniparental disomy of any chromosome, the percent and location of homozygosity, including the degree of identity by descent. It will also allow the detection of complete or partial molar pregnancies.

Methodology

SNP Microarray analysis is performed using the Oncoscan® FFPE platform, which uses more than 220,000 SNP probes with a median spacing of 5.0kb, within the majority of genes.

Collection instructions

Specimen should be fixed in 10% neutral-buffered formalin or formaldehyde. Improperly embedded preparation; decalcified bone or bone core; samples with no fetal visualized on pathology report; only a small area is identified on fixed sample as fetal and is less than 50% of sample cannot be processed.

Causes for rejection

Upon receipt, suitability of specimen will be determined by the Cytogenetics laboratory.

Special instructions

Pertinent medical findings should accompany the test request form. Please direct questions to genetic customer service at 800-345-4363. If prior NIPT studies have been performed, include copy of the report. There may be an additional charge for formalin positive tissue samples requiring embedding and pathology.

Limitations

This SNP assay does not detect balanced rearrangements, low-level mosaicism (<10%), marker chromosomes that only contain heterochromatin or tetraploidy. Genotypes in some formalin-fixed tissues are unable to be determined, allowing only genomic dosage to be determined. This test was developed and its performance characteristics determined by LabCorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
511998Specimen Type48002-0
N/A511997Reveal(R) POC Paraffin94087-4
511997Reveal(R) POC Paraffin94087-4
511997Reveal(R) POC Paraffin94087-4

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81229

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.