Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Reveal SNP Microarray and Abbreviated Chromosome Analysis (CVS)

Reveal SNP Microarray and Abbreviated Chromosome Analysis (CVS) (Reveal Snp Microarray And Abbreviated Chromosome Analysis Cvs Whe): Labcorp test 511555

Labcorp test 511555, CPT 81229, 88235, 88261, 88280. Specimen: Chorionic villi. Turnaround: 10 - 21 days.

Reveal SNP Microarray and Abbreviated Chromosome Analysis (CVS) is Labcorp test code 511555, billed with CPT 81229, 88235, 88261, 88280. Specimen: Chorionic villi. Turnaround time: 10 - 21 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code511555 (Reveal Snp Microarray And Abbreviated Chromosome Analysis Cvs Whe)
CPT81229; 88235; 88261; 88280
LOINC64086-2, 64087-0
SpecimenChorionic villi
Volume20 to 30 mg (for concurrent array and chromosomes)
Minimum volume5 mg for cultured array and chromosomes, 15 mg for direct array and cultured chromosomes
ContainerThe CVS transport tube (a sterile specimen container with transport medium) is available from Labcorp. Please call customer service at 800-345-4363.
Turnaround time10 - 21 days
Storage / transportMaintain specimen at room temperature, and transport it to the cytogenetics laboratory immediately. Do not freeze. Refrigerate if sterility is questioned or if sample cannot be shipped within 24 hours.

Also known as: CVS Chromosome Five-cell Count Plus Microarray (Reveal®)

Test includes

This test includes DNA extraction; interpretation; and limited five-cell chorionic villus sample (CVS) chromosome analysis (two analyses, one karyotype).

Use

The test allows prenatal detection of chromosomal aneuploidy, and is used to rule out tetraploidy and rearrangements not detected by array, such as balanced translocations and inversions. It also helps to clarify array abnormalities to determine if a structural rearrangement, marker, or isochromosome is present. Array can only provide copy number imbalances and cannot determine structure of an abnormality. The SNP assay will detect chromosomal imbalances that could be associated with developmental delay/congenital anomalies. It provides detection of possible uniparental disomy of any chromosome, the percent and location of homozygosity, including the degree of identity by descent.

Methodology

Five-cell G-Band Chromosome analysis; SNP microarray analysis is performed using the Cytoscan® HD Accel platform, which uses more than 743,130 SNP probes and 2,029,441 NPCN probes with a median spacing of 0.818 kb.

Collection instructions

Specimen is collected in syringe (transabdominal) or catheter (transcervical) and transferred by flushing with the media from the sterile container back into it. After collecting the specimen, wash with sterile saline solution (NaCl 0.95%) containing sodium heparin (two to three drops of sodium heparin in 10 mL of saline). Carefully transfer the specimen into the CVS transport tube using a sterile Pasteur pipette or a sterile fine needle forceps. Be sure to fill transport tubes completely with medium. Samples from twin (multiple) pregnancies should be appropriately labeled and placed in separate transport containers with a separate test request form for each twin. No villi submitted in specimen; improperly labeled specimen; frozen specimen or specimen placed in fixative will be processed.

Causes for rejection

Upon receipt, suitability of specimen will be determined by the Cytogenetics laboratory.

Special instructions

A completed Clinical Questionnaire for SNP Microarray should accompany specimens. Call 800-345-4363 to request the appropriate form, or photocopy the form from Genetics Appendix. Concurrent maternal contamination (MCC) studies are required; submit maternal blood (EDTA) using Maternal Cell Contamination [511402] . If prior NIPT studies have been performed, include copy of the report. This test includes a limited five-cell chorionic villi sample (CVS) chromosome analysis, which includes two analyses and one karyotype. This test is used to rule out tetraploidy and balanced translocations and inversions not detected by microarray analysis. If specimens from a twin pregnancy are submitted by request, it can be reported if these are DZ or MZ twins. Gender by ultrasound is recommended when possible. If the CVS specimen does not meet requirements for microarray testing, array testing will be run on cultures. If cultures are needed and performed by Labcorp, additional days will be required to complete testing. A delay notification will be sent to the client if cultures are necessary.

Limitations

This SNP assay does not detect balanced rearrangements, low-level mosaicism (<10%), marker chromosomes that only contain heterochromatin or tetraploidy. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
CVS Chrom 5 Cell Cnt + CMA510194Cells Analyzed64086-2
CVS Chrom 5 Cell Cnt + CMA510197GTG Band Resolution64087-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81229, 88235, 88261

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation