Sound Lab Consultants › National Lab Test Directory › Labcorp › Anti-Aquaporin 4 (AQP4), Spinal Fluid

Anti-Aquaporin 4 (AQP4), Spinal Fluid: Labcorp test 505758

Labcorp test 505758, CPT 86052. Specimen: Cerebrospinal fluid (CSF). Turnaround: 1 - 2 Days.

Anti-Aquaporin 4 (AQP4), Spinal Fluid is Labcorp test code 505758, billed with CPT 86052. Specimen: Cerebrospinal fluid (CSF). Turnaround time: 1 - 2 Days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code505758
CPT86052
LOINC90818-6
SpecimenCerebrospinal fluid (CSF)
Volume2 mL
Minimum volume1 mL ( Note: This volume does not allow for repeat testing.)
ContainerCSF sterile tube
Turnaround time1 - 2 Days
Storage / transportRoom temperature

Use

This test is used for evaluation of patients with suspected Neuromyelitis Optica Spectrum Disorder (NMOSD). Testing for Neuromyelitis Optica (NMO) Spectrum should be considered in patients presenting with optic neuritis, transverse myelitis, and/or area postrema clinical syndrome, which consists of intractable hiccups or nausea and vomiting. NMOSD diagnosis is based on core clinical characteristics, antibody status and features as detected by magnetic resonance neuroimaging. All of these components are included in the International Panel for NMO Diagnosis (IPND) 2015 revised consensus criteria. Laboratory testing involves determining AQP4 IgG and MOG IgG serum antibody status; the presence…

Methodology

Immunofluorescence (IFA)

Collection instructions

Collect CSF in a sterile tube.

Stability

TemperaturePeriod
Room temperature7 days
Refrigerated7 days
Frozen7 days
Freeze/thaw cyclesStable x3

Special instructions

If reflex test is performed, additional charges/CPT code(s) may apply.

Limitations

The absence of AQP4 antibodies does not rule out the diagnosis of NMOSD because false-negative results may occur in the setting of immunosuppression. Occasionally, patients without detectable serum AQP4 IgG are later found to be seropositive; antibody levels increase with clinical relapse and decrease with immunosuppressive therapy. Retesting should be considered before B-cell- or antibody-targeted therapies are instituted and in patients with seronegative results who relapse. AQP4 titers may increase but may not be predictive of relapses or attacks. AQP4 antibodies may become undetectable with immunosuppression, but this does not necessarily indicate clinical response. Results should not…

LOINC map

Result codeResult nameUnitsResult LOINC
505757Anti-AQP4, CSF, Cell-based IFA90818-6

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86052

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation