Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › c-KIT Mutation Analysis in Tumors of Hematopoietic Tissue

c-KIT Mutation Analysis in Tumors of Hematopoietic Tissue (C Kit Mutation Analysis In Tumors Of Hematopoietic Tissue): Labcorp test 480940

Labcorp test 480940, CPT 81272. Specimen: Whole blood or bone marrow. Turnaround: 10 - 14 days.

c-KIT Mutation Analysis in Tumors of Hematopoietic Tissue is Labcorp test code 480940, billed with CPT 81272. Specimen: Whole blood or bone marrow. Turnaround time: 10 - 14 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code480940 (C Kit Mutation Analysis In Tumors Of Hematopoietic Tissue)
CPT81272
LOINC48004-6, 48005-3, 49549-9, 55201-8, 77202-0
SpecimenWhole blood or bone marrow
Volume3 to 5 mL whole blood or 1 to 2 mL bone marrow
Minimum volume3 mL whole blood or 1 mL bone marrow
ContainerLavender-top (EDTA) tube, green-top (sodium heparin) tube, tan-top (K2-EDTA) tube or pink-top (K2-EDTA) tube
Turnaround time10 - 14 days
Storage / transportShip at room temperature; if specimen is stored prior to shipment, store at 2°C to 8°C.

Use

c-KIT is a proto-oncogene that encodes a type III transmembrane tyrosine kinase. c-KIT and its ligand stem cell factor have a key role in survival, proliferation, differentiation and functional activation of hematopoietic progenitor cells. c-KIT mutations are reported in the majority of systemic mastocytosis cases. For KIT D816V mutation analysis by high sensitivity digital PCR, please see test KIT D816V Digital PCR. c-KIT mutations account for 20% to 40% in core-binding factor (CBF) acute myeloid leukemia (AML). c-KIT mutations also occur in MDS and contribute to MDS risk stratification. c-KIT mutation in AML confers increased risk of relapse and decreased overall survival. Tyrosine kinase…

Methodology

Polymerase chain reaction (PCR) and DNA sequencing

Collection instructions

Submit at room temperature. Indicate date and time of collection on the test request form.

Causes for rejection

Specimen does not meet all of the above criteria for sample type, container, minimum volume, collection and storage; unsuitable specimens include but are not limited to: frozen whole blood or marrow; a leaking tube; clotted blood or marrow; a grossly hemolyzed specimen or otherwise visibly degraded; specimen suspected of being contaminated by another specimen; specimen contains specific foreign material

Special instructions

Please direct any questions regarding this test to oncology customer service at 800-345-4363.

Limitations

Genomic DNA was purified from the provided specimen. Exons 8 and 17 of c-KIT gene coding were subjected to PCR amplification and bidirectional sequencing in duplicate to identify sequence variations. This assay has a sensitivity to detect approximately 10% population of cells containing the c-KIT mutations in a background of nonmutant cells. This assay will not detect the mutation below the sensitivity of the assay. Molecular-based testing is highly accurate but, as in any laboratory test, rare diagnostic errors may occur. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
480941c-KIT Mutation Analysis Result55201-8
480943Nucleotide Change:48004-6
480944Amino Acid Change:48005-3
480945Background:77202-0
480946Methodology:49549-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81272

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation