KIT Mutations Melanoma: ARUP Laboratories test 3004283
ARUP Laboratories test 3004283, CPT 81272, 81314. Specimen: Tumor tissue.. Turnaround: 10-12 days.
Also known as: c-KIT; TKI sensitivity; CD117 KIT; cKIT; KIT exons 9, 11,13, 14, 17, and 18; TKI resistance determination
Use
Use to detect activating mutations in KIT and PDGFRA . Use to predict response to tyrosine kinase inhibitor (TKI) therapy.
Methodology
Massively Parallel Sequencing
Collection instructions
Formalin fix (10 percent neutral buffered formalin) and paraffin embed tissue. Diff-Quik- and Papanicolaou-stained cytology smears are also acceptable. Number of slides needed is dependent on the tumor cellularity of the smear. Slide(s) will be destroyed during testing process and will not be returned to client. Protect from excessive heat. Transport block and/or slides in a tissue transport kit (ARUP supply # 47808 ) available online through eSupply using ARUP Connect™ or contact ARUP Client Services at 800-522-2787. Resections: Transport 8 unstained 5-micron slides. (Min: 5 slides) Small Biopsies: Transport 15 unstained 5-micron slides. (Min: 10 slides) New York State Clients: Transport tissue (Formalin-fixed, paraffin embedded) or 10 unstained, nonbaked slides and 1 slide stained with hematoxylin and eosin with at least 20% tumor nuclei
Stability
Ambient: Indefinitely; Refrigerated: Indefinitely; Frozen: Unacceptable
Causes for rejection
Less than 10 percent tumor. Specimens fixed in any fixative other than 10 percent neutral buffered formalin. Decalcified specimens. FNA smears with less than 50 tumor cells.
Reference range
By report
Remarks
Include surgical pathology report. If multiple specimens (blocks or slides) are sent to ARUP, they must be accompanied by one of the following: an order comment indicating that the ARUP pathologist should choose the specimen most appropriate for testing (e.g., "Choose best block"), or individual orders for each sample submitted. A Pathologist Block Selection Fee (ARUP test code 3002076) will be added to orders that utilize the first option. If multiple specimens are sent to ARUP without a request for pathologist block/slide selection or individual orders, they will be held until clarification is provided.
Performed
Varies
Compliance Category
Laboratory Developed Test (LDT)
New York DOH Approval Status
Testing is not New York state approved. Specimens from New York clients will be sent out to a New York state-approved laboratory.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 2002148 | Block ID | 57723-9 | |
| 2002694 | KIT Mutation, Melanoma Interpretation | 55201-8 |
View this test on ARUP Laboratories's website → · Last checked 2026-11-29
Other tests billed with CPT 81272, 81314
- c-KIT Mutation Analysis
- Gastrointestinal Stromal Tumor Mutations
- Gastrointestinal Stromal Tumors (GISTs), c-KIT Mutation Analysis
- Gastrointestinal Stromal Tumors (GISTs), c-KIT Mutation Analysis With Reflex to PDGFRA Mutation Analysis
- KIT and PDGFRA Mutation for GIST
- KIT Mutation for Melanoma
- Melanoma Mutation Panel
- c-KIT Mutation Analysis in Gastrointestinal Stromal Tumors (GISTs)
- c-KIT Mutation Analysis in Tumors of Hematopoietic Tissue
- Gastrointestinal Stromal Tumors (GISTs), PDGFRA Mutation Analysis
- PDGFRA Mutation Analysis in Gastrointestinal Stromal Tumors (GISTs)
Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation