Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Self-Collection in Office or Patient Service Center, Trichomonas vaginalis, Vaginal Swab, NAA

Self-Collection in Office or Patient Service Center, Trichomonas vaginalis, Vaginal Swab, NAA: Labcorp test 188024

Labcorp test 188024, CPT 87661. Specimen: Vaginal swab. Turnaround: 2 - 4 days.

Self-Collection in Office or Patient Service Center, Trichomonas vaginalis, Vaginal Swab, NAA is Labcorp test code 188024, billed with CPT 87661. Specimen: Vaginal swab. Turnaround time: 2 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code188024
CPT87661
LOINC11502-2, 46154-1
SpecimenVaginal swab
VolumeOne swab
Minimum volumeOne swab
ContainerAptima® Multitest Swab Specimen Collection Kit
Turnaround time2 - 4 days
Storage / transportMaintain specimen at room temperature or refrigerate (2°C to 30°C).

Also known as: Trichomonas, PCR

Use

This test is used for diagnosis of Trichomonas vaginalis infection.

Methodology

Nucleic acid amplification (NAA)

Collection instructions

Patient Self-Collection: Partially open the package of the APTIMA® vaginal swab kit. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down or the swab is dropped, use a new APTIMA® swab specimen collection kit. Remove the swab. Carefully insert the swab into the vagina about two inches past the introitus and gently rotate the swab for 10 to 30 seconds, making sure the swab touches the walls of the vagina so that moisture is absorbed by the swab. Withdraw the swab without touching the skin. Immediately place the swab into the transport tube and carefully break the swab shaft against the side of the tube. Tightly screw on the cap.

Stability

TemperaturePeriod
Room temperature60 days (stability provided by manufacturer or literature reference)
Refrigerated60 days (stability provided by manufacturer or literature reference)

Causes for rejection

Specimen with incorrect patient identification; unlabeled specimen; inappropriate specimen transport conditions; specimens received after prolonged delay (usually >72 hours); specimen leaked in transit; specimen in expired transport or incorrect transport device; specimens with inappropriate source for test requested; specimen with fixative or additives; APTIMA® swab transport >60 days from collection; APTIMA® swab specimens with incorrect specimen volume; APTIMA® swab specimen without a swab; cleaning swab (white-shaft swab) in APTIMA® swab transport; any non-Gen-Probe® swab submitted in APTIMA® transport device; wooden-shaft swab in transport device; transport device with multiple swabs; female urethral swab; bloody or grossly mucoid specimens; bacterial swabs; specimen in ProbeTec™ UPT transport; ProbeTec™ Q-swabs; UTM-RT

LOINC map

Result codeResult nameUnitsResult LOINC
188053Trich vag by NAA46154-1
019054PDF11502-2

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87661

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation