Mycobacterium tuberculosis Complex Detection and Rifampin Resistance, NAA With AFB Culture, Nonsputum: Labcorp test 183510
Labcorp test 183510, CPT 87116, 87564. Specimen: Bronchial washings or bronchoalveolar lavage (BAL) specimens, pleural fluid or cerebrospinal fluid (CSF). Turnaround: 48 - 56 days.
Use
This test is used to detect and identify Mycobacterium tuberculosis complex and an rpoB mutation that is associated with rifampin resistance.
Methodology
Nucleic acid amplification (NAA), nested real-time polymerase chain reaction (PCR); concentrated specimen with broth-based and/or agar-based culture. Culture is held for six weeks before negative is reported. Organisms from culture are identified by use of real-time polymerase chain reaction (PCR) and/or MALDI-TOF and/or nucleic acid sequencing.
Stability
| Temperature | Period |
|---|---|
| Refrigerated | 7 days |
Causes for rejection
Quantity not sufficient; inappropriate specimen source (i.e., not BAL, CSF or pleural fluid); specimen submitted on a swab; specimen received after leaking out of transport container into the specimen bag; inappropriate or expired specimen transport device; syringe with attached needle; unlabeled specimen container or container with a single patient identifier; name discrepancy between the specimen container label and the computer or the requisition; specimen received after prolonged delay (more than seven days); specimen in a paraffin block; specimen in a fixative; specimen at room temperature received after 72 hours; specimen received frozen
Limitations
The assay should not be used to test specimens from patients that have been treated with antituberculous drugs for more than three days. The assay should not be used to monitor therapy or as a test of cure. A negative test does not exclude the possibility of isolating M. tuberculosis complex isolates from culture. Assay interference may occur in the presence of lidocaine, mucin, ethambutol, guaifenesin, phenylephrine, and tea tree oil. Lower sensitivity may be observed in pediatric patients due to the diffuse nature of Mtb infection in the lungs of this patient group and difficulties encountered in obtaining adequate specimens. This test was developed and its performance characteristics…
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 183508 | Specimen Source | 31208-2 | |
| 183649 | M tuberculosis complex | 38379-4 | |
| 183650 | Rifampin Resistance | 89372-7 | |
| 183646 | AFB Specimen Processing | 8100-0 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 87116, 87564
- Acid-fast (Mycobacteria) Smear and Culture With Reflex to Identification
- Acid-fast (Mycobacteria) Smear and Culture With Reflex to Identification and Susceptibility Testing
- Acid-Fast Bacillus (AFB) Culture and AFB Stain
- Acid-Fast Bacillus (AFB) Culture and AFB Stain with Reflex to Mycobacterium tuberculosis Complex Detection and Rifampin Resistance by PCR
- Blood Culture, Acid-Fast Bacillus (AFB)
- Blood Culture, AFB and Fungal
- Mycobacterium tuberculosis Complex Detection and Rifampin Resistance (PCR), Acid-fast Bacillus (AFB) Smear, and AFB Culture (Sputum)
- Mycobacterium tuberculosis Complex Detection and Rifampin Resistance (PCR), Acid-fast Bacillus (AFB) Smear, and AFB Culture With Reflex to Identification (Nonsputum)
- Mycobacterium tuberculosis Complex Detection and Rifampin Resistance (PCR), Acid-fast Bacillus (AFB) Smear, and AFB Culture With Reflex to Identification and Susceptibility Testing (Nonsputum)
- Mycobacterium tuberculosis Complex Detection and Rifampin Resistance (PCR), Acid-fast Bacillus (AFB) Smear, and AFB Culture With Reflex to Identification and Susceptibility Testing (Sputum)
- Mycobacterium tuberculosis Complex Detection and Rifampin Resistance, NAA With AFB Culture
- Mycobacterium tuberculosis Complex Detection and Rifampin Resistance by PCR
- Send Out MTB Detection and Rifampin Resistance by PCR (CSF, Pleural fluid)
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation