Sound Lab Consultants › National Lab Test Directory › Labcorp › Mycobacterium tuberculosis Complex Detection and Rifampin Resistance, NAA With AFB Culture

Mycobacterium tuberculosis Complex Detection and Rifampin Resistance, NAA With AFB Culture: Labcorp test 183469

Labcorp test 183469, CPT 87116, 87564. Specimen: Sputum (adult population) first morning specimen. Turnaround: 48 - 56 days.

Mycobacterium tuberculosis Complex Detection and Rifampin Resistance, NAA With AFB Culture is Labcorp test code 183469, billed with CPT 87116, 87564. Specimen: Sputum (adult population) first morning specimen. Turnaround time: 48 - 56 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code183469
CPT87116; 87564
LOINC14556-5, 33634-7, 8100-0, 89371-9
SpecimenSputum (adult population) first morning specimen
Volume2 mL of raw or expectorated sputum
Minimum volume2 mL
ContainerSterile screw-capped vial or sterile cup; seal securely
Turnaround time48 - 56 days
Storage / transportRefrigerate. If sample is to be split for other tests, specimen should be divided at the time of collection so that each portion is transported at the appropriate temperature.

Use

This test is used to detect and identify Mycobacterium tuberculosis complex and an rpoB mutation that is associated with rifampin resistance.

Methodology

Nucleic acid amplification (NAA), nested real-time polymerase chain reaction (PCR); concentrated specimen with broth-based and/or agar-based culture. Culture is held for six weeks before negative is reported. Organisms from culture are identified by use of real-time polymerase chain reaction (PCR) and/or MALDI-TOF and/or nucleic acid sequencing.

Stability

TemperaturePeriod
Refrigerated7 days

Patient preparation

When collecting sputum, have the patient brush teeth or remove dentures and rinse mouth with water. Instruct the patient not to collect saliva.

Causes for rejection

Quantity not sufficient; inappropriate specimen source (i.e., not sputum); specimen received after leaking out of transport container into the specimen bag; inappropriate transport device; unlabeled specimen container or container with a single patient identifier; name discrepancy between the specimen container label and the computer or the requisition; specimen received after prolonged delay (more than seven days); specimen in a paraffin block; specimen in a fixative; specimen at room temperature received after 72 hours; specimen submitted frozen

Limitations

The assay should not be used to test specimens from patients that have been treated with antituberculous drugs for more than three days. The assay should not be used to monitor therapy or as a test of cure. A negative test does not exclude the possibility of isolating M. tuberculosis complex isolates from culture. Assay interference may occur in the presence of lidocaine, mucin, ethambutol, guaifenesin, phenylephrine, and tea tree oil. Lower sensitivity may be observed in pediatric patients due to the diffuse nature of Mtb infection in the lungs of this patient group and difficulties encountered in obtaining adequate specimens.

LOINC map

Result codeResult nameUnitsResult LOINC
183457M tuberculosis complex14556-5
183455Rifampin Resistance33634-7
008619AFB Specimen Processing8100-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87116, 87564

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation