Labcorp test 182893, CPT 86480. Specimen: Whole blood. Turnaround: 2 - 5 days.

QuantiFERON®-TB Gold Plus (Client Incubated) is Labcorp test code 182893, billed with CPT 86480. Specimen: Whole blood. Turnaround time: 2 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code182893 (Women's Health)
CPT86480
LOINC64084-7, 71774-4, 71775-1, 71776-9, 8251-1, 88517-8
SpecimenWhole blood
Volume1 mL x four tubes in QuantiFERON-TB Gold Plus kit
Minimum volume1 mL x four tubes in QuantiFERON-TB Gold Plus kit
ContainerThe QuantiFERON®-TB Gold Plus collection kit contains the instructions for the collection and handling of (one each): (1) gray-top (with white ring), uncoated (nil); (2) green cap with white ring, TB1 tube; (3) yellow cap with white ring, TB2 tube; (4) purple top with white ring, mitogen-coated. A high altitude kit is also available for locations between 3350 and 6150 feet; a cap with a yellow ring differentiates the tubes.
Turnaround time2 - 5 days
Storage / transportBefore incubation at 37°C, maintain specimen at room temperature. Stability: Kit must be incubated within 16 hours of collection. After incubation, maintain specimen at room temperature (17°C to 27°C). Do not centrifuge, refrigerate, or ship tubes on ice.

Also known as: Interferon-gamma Release Assay (IGRA) for Mycobacterium tuberculosis; QFT-Plus

Use

QuantiFERON-TB Gold Plus is an in vitro diagnostic test using a peptide cocktail of CD4+ and CD8+ T cell antigens to stimulate cells in heparinized whole blood. Detection of interferon-gamma by enzyme-linked immunosorbent assay (ELISA) is used to identify in vitro responses to these peptide antigens that are associated with Mycobacterium tuberculosis infection. QuantiFERON-TB Gold Plus is an indirect test for M. tuberculosis infection (including disease) and is intended for use in conjunction with risk assessment, radiography, and other medical and diagnostic evaluations.

Methodology

Whole blood interferon-gamma test measuring responses to CD4+ and CD8+ T cell antigens

Collection instructions

Blood collection tubes should be at room temperature at the time of collection. Refer to collection instructions included with draw kit. Special specimen collection kit contains four gel-barrier tubes as noted above. All four tubes are required for a single test result. Each tube is designed to draw only 1 mL and fill time may be longer than other blood collection tubes. Because of the limited vacuum in these tubes, use a needle and holder ( not a butterfly) to collect QuantiFERON® specimens. If a butterfly is required, first collect other required tubes or use another Vacutainer® tube to purge the butterfly line of air and then proceed with drawing the QuantiFERON tubes. Fill tubes to the black fill line on the tube. If tubes are underfilled or overfilled (see kit insert), immediately collect a replacement tube. Following proper fill, label the tubes appropriately and shake tubes 10 times firmly enough to ensure the entire surface of the tube is coated with blood cells to solubilize the antigen on the tube walls. After shaking, the volume may fall below the fill line. Do not centrifuge or refrigerate specimens. Return each of the four properly filled, labeled and shaken tubes to the box labeled "QFT kit." Seal the top by removing tape from the adhesive. Finally, label the box as "Client Incubated."

Causes for rejection

Grossly hemolyzed, icteric, or lipemic samples; expired collection tubes; specimen centrifuged, refrigerated, or frozen; specimen more than 94 hours old on receipt by lab; receipt of three tube collection kit; under-filled or over-filled tubes; tubes that do not yield sufficient plasma for testing

Special instructions

This test is time-sensitive . Specimens must be incubated at 37°C for 16 to 24 hours prior to transport to LabCorp and specimens must be received in the laboratory within 70 hours after incubation by the client (no more than 94 hours from the time of collection). Specimen collection times will be dependent on logistics from the incubating location to a Labcorp lab. To submit QuantiFERON-TB Gold Plus specimens that are not client incubated prior to submission, order QuantiFERON®-TB Gold Plus (Test No. 182879).

Limitations

A negative QFT-Plus result does not preclude the possibility of M. tuberculosis infection or tuberculosis disease: false negative results can be due to stage of infection, co-morbid conditions that affect immune function, incorrect handling of the blood collection tubes following venipuncture, incorrect performance of the assay, or other individual immunological variables. Heterophile antibodies or non-specific interferon-gamma production from other inflammatory conditions may mask specific responses to CD4+ and CD8+ T cell antigens. A positive QFT-Plus result should not be the sole or definitive basis for determining infection with M. tuberculosis. Incorrect performance of the assay may…

LOINC map

Result codeResult nameUnitsResult LOINC
182885QuantiFERON Criteria8251-1
182886QuantiFERON TB1 Ag ValueIU/mL64084-7
182887QuantiFERON TB2 Ag ValueIU/mL88517-8
182891QuantiFERON Nil ValueIU/mL71776-9
182892QuantiFERON Mitogen ValueIU/mL71774-4

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86480

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation