Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › QuantiFERON®-TB Gold Plus

QuantiFERON®-TB Gold Plus: Labcorp test 182879

Labcorp test 182879, CPT 86480. Specimen: Whole blood. Turnaround: 2 - 5 days.

QuantiFERON®-TB Gold Plus is Labcorp test code 182879, billed with CPT 86480. Specimen: Whole blood. Turnaround time: 2 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code182879
CPT86480
LOINC71773-6, 8251-1
SpecimenWhole blood
Volume1 mL x four tubes in QuantiFERON-TB Gold Plus kit
Minimum volume1 mL x four tubes in QuantiFERON-TB Gold Plus kit
ContainerThe QuantiFERON®-TB Gold Plus collection kit contains the instructions for the collection and handling of (one each): (1) gray-top (with white ring), uncoated (nil); (2) green cap with white ring, TB1 tube; (3) yellow cap with white ring, TB2 tube; (4) purple top with white ring, mitogen-coated. A high-altitude kit is also available for locations between 3350 and 6150 feet; a cap with a yellow ring differentiates the tubes.
Turnaround time2 - 5 days
Storage / transportMaintain specimen at room temperature for four tube collection kit. Stability: Kit must be incubated within 16 hours of collection.

Also known as: Interferon-gamma Release Assay (IGRA) for Mycobacterium tuberculosis; QFT-Plus

Use

QuantiFERON-TB Gold Plus is an in vitro diagnostic test using a peptide cocktail of CD4+ and CD8+ T cell antigens to stimulate cells in heparinized whole blood. Detection of interferon-gamma by enzyme-linked immunosorbent assay (ELISA) is used to identify in vitro responses to these peptide antigens that are associated with Mycobacterium tuberculosis infection. QuantiFERON-TB Gold Plus is an indirect test for M. tuberculosis infection (including disease) and is intended for use in conjunction with risk assessment, radiography, and other medical and diagnostic evaluations.

Methodology

Whole blood interferon-gamma test measuring responses to CD4+ and CD8+ T cell antigens

Collection instructions

Blood collection tubes should be at room temperature at the time of collection. Refer to collection instructions included with draw kit. Special specimen collection kit contains four gel-barrier tubes as noted above. All four tubes are required for a single test result. Each tube is designed to draw only 1 mL and fill time may be longer than other blood collection tubes. Because of the limited vacuum in these tubes, use a needle and holder ( not a butterfly) to collect QuantiFERON® specimens. If a butterfly is required, first collect other required tubes or use another Vacutainer® tube to purge the butterfly line of air and then proceed with drawing the QuantiFERON tubes. Fill tubes to the black fill line on the tube. If tubes are underfilled or overfilled (see kit insert), immediately collect a replacement tube. Following proper fill, label the tubes appropriately and shake tubes 10 times firmly enough to ensure the entire surface of the tube is coated with blood cells to solubilize the antigen on the tube walls. After shaking, the volume may fall below the fill line. Do not centrifuge or refrigerate specimens. Return each of the four properly filled, labeled, and shaken tubes to the box labeled "QFT kit." Seal the top by removing tape from the adhesive. To preserve cellular viability, specimens should be collected and sent the same day, at room temperature, so as to arrive at the lab as soon as possible and within 14 hours of collection.

Causes for rejection

Grossly hemolyzed, icteric, or lipemic samples; expired collection tubes. Four tube QuantiFERON collection kit: Specimen centrifuged, refrigerated, or frozen; specimen more than 14 hours old on receipt by lab; receipt of three tube collection kit; under-filled or over-filled tubes; tubes that do not yield sufficient plasma for testing.

Special instructions

QuantiFERON is time-sensitive and specimens must be received in the laboratory within 14 hours of collection. Specimen collection times will vary depending on logistics from the blood draw location to a Labcorp lab. This test requires a special collection kit that may not be available at all PSCs. To submit QuantiFERON specimens that are client-incubated, order QuantiFERON®-TB Gold Plus (Client Incubated) (Test No. 182893).

Limitations

A negative QFT-Plus result does not preclude the possibility of M. tuberculosis infection or tuberculosis disease: false negative results can be due to stage of infection, co-morbid conditions that affect immune function, incorrect handling of the blood collection tubes following venipuncture, incorrect performance of the assay, or other individual immunological variables. Heterophile antibodies or non-specific interferon-gamma production from other inflammatory conditions may mask specific responses to CD4+ and CD8+ T cell antigens. A positive QFT-Plus result should not be the sole or definitive basis for determining infection with M. tuberculosis . Incorrect performance of the assay may…

LOINC map

Result codeResult nameUnitsResult LOINC
182889QuantiFERON Incubation8251-1

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86480

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation