Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Helicobacter pylori Urea Breath Test

Helicobacter pylori Urea Breath Test: Labcorp test 180836

Labcorp test 180836, CPT 83013. Specimen: Breath samples pre- and post-ingestion of fruit-flavored powder solution, containing C-urea diagnostic component.. Turnaround: 1 - 4 days.

Helicobacter pylori Urea Breath Test is Labcorp test code 180836, billed with CPT 83013. Specimen: Breath samples pre- and post-ingestion of fruit-flavored powder solution, containing C-urea diagnostic component.. Turnaround time: 1 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code180836
CPT83013
LOINC29891-9
SpecimenBreath samples pre- and post-ingestion of fruit-flavored powder solution, containing C-urea diagnostic component.
VolumeOne pre- and one post-ingestion breath sample
ContainerOne blue sample bag labeled “baseline” and one "postdose" sample bag
Turnaround time1 - 4 days
Storage / transportMaintain specimen at room temperature.

Also known as: Ubit; Urea Breath Test

Test includes

Analysis of pre- and postbreath samples to detect CO 2

Use

The urea breath test can be used to aid in the diagnosis of H pylori infection. The test can also be used to assess therapy when it is administered more than a month after completion of therapy.

Methodology

IR (infrared) spectroscopy to assess the presence of CO 2

Collection instructions

Blue sample bag (baseline) must be collected as follows: • Remove the blue breath collection bag from the kit. • Remove the pulloff cap from mouthpiece of the breath collection bag. • Instruct the patient to breathe normally, then take a deep breath, pause holding their breath for a full second (counting one, one thousand) then exhale into the mouthpiece of the bag. • Replace the cap in the mouth piece of the bag. Prepare the fruit-flavored powder solution, containing C-urea diagnostic component as detailed in the kit instructions Postdose sample bag is collected as follows: • Instruct the patient to drink all the solution without “rinsing” mouth before swallowing. • Have the patient sit quietly for 15 minutes. Set timer for 15 minutes. • After 15 minutes, collect the gray sample bag as outlined for the baseline specimen above. All sample bags must be labeled according to Labcorp specimen labeling policies.

Patient preparation

The patient should fast for at least one hour prior to testing. The patient should not take antimicrobials, proton pump inhibitors, or bismuth preparations within two weeks prior to testing. Note: Solution contains phenylalanine. Phenylketonurics should be warned.

Causes for rejection

Prolonged transport more than seven days; specimens collected from persons younger than 3 years of age

Reference range

Negative

Special instructions

This test can be performed on adult patients and pediatric patients between the ages of 3 and 17.

LOINC map

Result codeResult nameUnitsResult LOINC
180835H pylori Breath Test29891-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83013

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation