Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Helicobacter pylori , Breath Test

Helicobacter pylori , Breath Test: ARUP Laboratories test 3006271

ARUP Laboratories test 3006271, CPT 83013. Specimen: Breath Test Kit IDkit Hp Two (ARUP Supply # 58132 ) available online through e-Supply using ARUP Connect(TM) or contact . Turnaround: 1-4 days.

Helicobacter pylori , Breath Test is ARUP Laboratories test code 3006271, billed with CPT 83013. Specimen: Breath Test Kit IDkit Hp Two (ARUP Supply # 58132 ) available online through e-Supply using ARUP Connect(TM) or contact ARUP Client Services. Turnaround time: 1-4 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), Labcorp.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code3006271
CPT83013
LOINC29891-9
SpecimenBreath Test Kit IDkit Hp Two (ARUP Supply # 58132 ) available online through e-Supply using ARUP Connect(TM) or contact ARUP Client Services at 800-522-2787.
Turnaround time1-4 days
Storage / transportCRITICAL ROOM TEMPERATURE. Do not freeze. Protect bags from sharp objects and direct sunlight. Refrain from applying any external pressure on the breath sample bags.

Also known as: 13C Urea Breath Test; BreathID; H pylori; H. pylori Urea Breath Test; Helicobactor; Helicobactor pyl

Use

Aids in the initial diagnosis and posttreatment monitoring of Helicobacter pylori infection in adult patients and in pediatric patients 3-17 years of age. Posttreatment monitoring of H. pylori should be performed no sooner than 6 weeks after treatment for H. pylori infection. Earlier assessment may give false results.

Methodology

Qualitative Spectrophotometry

Collection instructions

1) Label breath collection bags with patient name, MRN, date and time of collection, and indicate Baseline (blue) or Post Ingestion (gray). 2) Collect the blue Baseline specimen according to the instructions in the Breath Test Kit, IDkit Hp Two. Instruct the patient to hold their breath for 4-5 seconds, and then exhale into the blue Baseline collection bag until the bag is full. 3) Prepare the test drink by adding 150 to 200 mL (5.1 to 6.8 oz.) water, the Citrica Powder, and the urea tablet to the provided drinking cup, closing the lid firmly, and shaking thoroughly until the powder and tablet are completely dissolved. 4) Administer the test drink within two hours of preparation per kit instructions and precautions. Regardless of age and body weight, the patient must consume the entire solution through the provided straw within 2 minutes. 5) Collect the gray Post Ingestion specimen 15 minutes after ingestion of the test drink, but no later than 20 minutes post ingestion. Instruct the patient to hold their breath for 4-5 seconds, and then exhale into the gray Post Ingestion collection bag until the bag is full. 6) Ensure the caps on the bag mouthpieces are secured (push until they click).

Stability

Ambient: 2 weeks; Refrigerated: Unacceptable; Frozen: Unacceptable.

Patient preparation

Remind the patient that there is 84 mg of phenylalanine per packet of Citrica Powder. Phenylketonurics restrict dietary phenylalanine. The patient should have fasted at least one hour before administering the solution. The patient should not have taken antimicrobials (i.e., antibiotics), proton pump inhibitors (e.g., Prilosec, Prevacid, Aciphex, Nexium, Zegerid, Dexilant, Protonix), or bismuth preparations (e.g., Pepto Bismol) within two weeks prior to administering the test. The effect of histamine 2-receptor antagonists (e.g., Axid, Pepcid, Tagamet, Zantac) may reduce urease activity and should be discontinued 24-48 hours before the sample is collected. Use of antacids (e.g., Tums, Milk of Magnesia, Rolaids, Mylanta, Gaviscon, Alka-Seltzer) does not appear to affect the accuracy of the test.

Causes for rejection

Underinflated or uncapped bags. Specimens from patients younger than 3 years. Specimens collected using the BreathTek UBT Kit (blue and pink collection bags).

Reference range

Test Number Components Reference Interval H. pylori, Breath Test Negative

Performed

Sun-Sat

Compliance Category

FDA

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
3006272H. pylori, Breath Test29891-9

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 83013

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation