Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Mycoplasma genitalium, NAA, Swab With Reflex to Macrolide Resistance Testing

Mycoplasma genitalium, NAA, Swab With Reflex to Macrolide Resistance Testing: Labcorp test 180092

Labcorp test 180092, CPT 87563. Specimen: Endocervical, vaginal or male urethral swab in Aptima® swab transport. Turnaround: 3 - 4 days.

Mycoplasma genitalium, NAA, Swab With Reflex to Macrolide Resistance Testing is Labcorp test code 180092, billed with CPT 87563. Specimen: Endocervical, vaginal or male urethral swab in Aptima® swab transport. Turnaround time: 3 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code180092
CPT87563
LOINC100706-1
SpecimenEndocervical, vaginal or male urethral swab in Aptima® swab transport
VolumeOne Aptima® swab (endocervical, vaginal or male urethral)
Minimum volumeOne Aptima® swab (endocervical, vaginal or male urethral)
ContainerAptima® Multitest Swab Specimen Collection Kit (preferred) or Aptima® Unisex Swab Specimen Collection Kit
Turnaround time3 - 4 days
Storage / transportMaintain specimen at room temperature or refrigerate (2°C to 30°C).

Use

This test is used to detect the presence of Mycoplasma genitalium in genital-based swab collections. If M. genitalium is detected, further testing for the presence of macrolide resistance will be performed.

Methodology

Nucleic acid amplification (NAA)

Collection instructions

Vaginal swab: Collect vaginal fluid sample using the Aptima® swab by contacting the swab to the lower third of the vaginal wall and rotating the swab for 10 to 30 seconds to absorb fluid. Immediately place the swab into the transport tube and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Endocervical swab: Remove excess mucus from the cervical os and surrounding mucosa using the cleaning swab (white-shaft swab in the package with red printing). Discard this swab. Insert the specimen collection swab (blue-shaft swab in the package with green printing) into the endocervical canal. Gently rotate the swab clockwise for 10 to 30 seconds in the endocervical canal to ensure adequate sampling. Withdraw the swab carefully; avoid contact with the vaginal mucosa. Remove the cap from the swab specimen transport tube and immediately place the specimen collection swab into the transport tube. Carefully break the swab shaft at the scoreline; use care to avoid splashing of the contents. Recap the swab specimen transport tube tightly. Male urethral swab: The patient should not have urinated for at least one hour prior to specimen collection. Insert the specimen collection swab (blue-shaft swab in the package with the green printing) 2 to 4 cm into the urethra. Gently rotate the swab clockwise for two to three seconds in the urethra to ensure adequate sampling. Withdraw the swab carefully. Remove the cap from the swab specimen transport tube and immediately place the specimen collection swab into the specimen transport tube. Carefully break the swab shaft at the scoreline; use care to avoid splashing of contents. Recap the swab specimen transport tube tightly.

Stability

TemperaturePeriod
Room temperature30 days (stability provided by manufacturer or literature reference)
Refrigerated30 days (stability provided by manufacturer or literature reference)

Special instructions

If reflex testing is performed, additional charges/CPT code(s) may apply.

Limitations

A negative result does not preclude a possible infection. Test results may be affected by improper specimen collection or target levels below the assay limit of detection (LoD). Results from this testing should be interpreted in conjunction with other clinical and laboratory data available to the clinician. Reliable results are dependent on adequate specimen collection, transport, storage and processing. Failure to observe proper procedures in any one of these steps can lead to incorrect results. The macrolide resistance test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration. The FDA has…

LOINC map

Result codeResult nameUnitsResult LOINC
180095Mycoplasma genitalium NAA100706-1

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87563

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation