Twin Zygosity Study: Labcorp test 176548

Labcorp test 176548, CPT 81265. Specimen: Whole blood or buccal swabs; other samples, such as amniotic fluid, cultured cells, and tissue specimens, may be used.. Turnaround: 3 - 7 days.

Twin Zygosity Study is Labcorp test code 176548, billed with CPT 81265. Specimen: Whole blood or buccal swabs; other samples, such as amniotic fluid, cultured cells, and tissue specimens, may be used.. Turnaround time: 3 - 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code176548
CPT81265
LOINC—
SpecimenWhole blood or buccal swabs; other samples, such as amniotic fluid, cultured cells, and tissue specimens, may be used.
Volume3 mL whole blood or four buccal swabs; other tissue as available.
ContainerLavender-top (EDTA) tube or four buccal swabs in a sealed envelope (buccal swab kit). Amniotic fluid and tissue in appropriate transport container. When submitting buccal swabs, please use a buccal swab kit provided by LabCorp. To obtain the buccal swab kit, please telephone 800-533-1037.
Turnaround time3 - 7 days
Storage / transportMaintain blood specimen at room temperature and keep dry.

Also known as: Dizygosity Study; Fraternal Twin Test; Identical Twin Test; Monozygotic and Dizygotic Twin Diagnosis; Zygosity Studies

Use

Provide evidence that twins are monozygotic versus dizygotic. This test may be used for legal purposes, obstetric management, as part of a transplant evaluation, and for other purposes.

Methodology

DNA analysis by polymerase chain reaction (PCR)

Causes for rejection

Improperly labeled specimen; improperly filled out client authorization/chain-of-custody form; insufficient amount of DNA on buccal swabs

Reference range

If the twins do not have identical results, the report will conclude the twins are dizygotic. If the twins have identical results, a statistical assessment of the probability they are monozygotic is provided. The monozygotic probability assessment will typically exceed 99.0%.

Special instructions

Include race/ethnicity and gender of the twins. Samples being tested at the request of a clinical account must have a completed test request form. If this study is collected for legal purposes, appointments and paternity kits are required. Specimens for legal testing must be collected with chain-of-custody paper work. To receive a complete paternity kit, blood or buccal swab, or for an appointment for legal testing, telephone 800-742-3844.

Limitations

The probability that twins are monozygotic is a statistical assessment and, as such, even though the twins have identical results and a high probability of being monozygotic, there is always a small probability that the twins are dizygotic. This chance is reflected in the probability provided. The statistical assessment can be improved by the submission of the parents of the twins. This test was developed, and its performance characteristics determined, by LabCorp. This test has not been cleared or approved by the US Food and Drug Administration (FDA). The FDA has determined that such clearance is not necessary.

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81265

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation