Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › BMT Engraftment Analysis, Pre-BMT, Recipient

BMT Engraftment Analysis, Pre-BMT, Recipient: Michigan Medicine Laboratories (MLabs) test RECBM

Michigan Medicine Laboratories (MLabs) test RECBM, CPT 81265. Specimen: 5 mL EDTA (lavender) whole blood. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.. Turnaround: 2 - 7 days.

BMT Engraftment Analysis, Pre-BMT, Recipient is Michigan Medicine Laboratories (MLabs) test code RECBM, billed with CPT 81265. Specimen: 5 mL EDTA (lavender) whole blood. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.. Turnaround time: 2 - 7 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Labcorp.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeRECBM
CPT81265
LOINC—
Specimen5 mL EDTA (lavender) whole blood. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.
Volume5 mL EDTA (lavender) whole blood. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.
Turnaround time2 - 7 days

Also known as: Bone Marrow Transplant Engraftment Evaluation; Polymorphism Detection, pre-BMT; Pre-BMT Engraftment Analysis, Recipent; Pre-BMT Polymorphism Detection; VNTR for pre-BMT Engraftment Analysis; Recipient BM Engraph. Eval; Chimerism Analysis, Pre-Transplant, Recipient

Use

To detect genetic polymorphism between the patient (recipient) and the donor prior to the bone marrow transplant, in order to evaluate the engraftment status after the transplant.

Collection instructions

Collect blood in a lavender top tube. Refrigerate and send intact blood or bone marrow specimen within 48 hours of collection.

Reference range

Interpretive report provided.

Limitations

If the patient has a very low white blood cell count, the DNA yield may be insufficient to complete the analysis. In order to perform this test, both the patient's pre-transplant and the donor's specimen must be available.

Section

Molecular Diagnostics

NY State approved

No

Alternate specimens

The preferred specimen is whole blood collected in EDTA (lavender top). However, ACD (yellow top) and heparin (green top) may also be accepted.

Performing Laboratory

Molecular Diagnostics

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 81265

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation