Myasthenia Gravis Profile: Labcorp test 165620

Labcorp test 165620, CPT 86041, 86042, 86043, 86255. Specimen: Serum. Turnaround: 6 - 8 days.

Myasthenia Gravis Profile is Labcorp test code 165620, billed with CPT 86041, 86042, 86043, 86255. Specimen: Serum. Turnaround time: 6 - 8 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Quest Diagnostics.
LaboratoryLabcorp
CLIA number34D0655059
Test code165620
CPT86041; 86042; 86043; 86255
LOINC11034-6, 11561-8, 5372-8, 55397-4, 99062-2
SpecimenSerum
Volume4 mL divided into two tubes
Minimum volume2 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time6 - 8 days
Storage / transportRefrigerate.

Test includes

Acetylcholine Receptor (AChR)-binding Antibodies; Acetylcholine Receptor (AChR)-blocking Antibodies; Acetylcholine Receptor (AChR)-modulating Antibodies; Striational Antibodies. Reflex criteria: If Acetylcholine Receptor (AChR)-binding and blocking are normal, will reflex to Muscle Specific Kinase (MuSK) Antibodies.

Use

Tests for the laboratory diagnosis of myasthenia gravis (MG)

Methodology

See individual tests.

Collection instructions

Allow a minimum clotting time of 30 to 60 minutes with serum separation within 2 hours of collection. Send serum samples in plastic transport tubes.

Stability

TemperaturePeriod
Room temperature7 days (stability provided by manufacturer or literature reference)
Refrigerated14 days (stability provided by manufacturer or literature reference)
Frozen14 days (stability provided by manufacturer or literature reference)
Freeze/thaw cyclesStable x3 (stability provided by manufacturer or literature reference)

Patient preparation

No isotopes administered 24 hours prior to venipuncture.

Causes for rejection

Excessive hemolysis; chylous serum; recently administered radioisotopes; plasma specimen

Special instructions

This assay currently is not available in New York state.

Limitations

In rare cases AChR antibodies can be found in patients with other autoimmune disorders or with thymoma without MG. The causative autoantibody cannot be identified in up to 10 percent of patients with MG. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
085904AChR Binding Abs, Serumnmol/L11034-6
085927AChR Blocking Abs, Serum%11561-8
505199AChR-modulating Ab%99062-2
161216Striation Abs, Serum5372-8

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86041, 86042, 86043

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation