Scleroderma Comprehensive Plus Profile (RDL): Labcorp test 520130
Labcorp test 520130, CPT 83516, 86038, 86235. Specimen: Serum. Turnaround: 14 - 21 days.
Scleroderma Comprehensive Plus Profile (RDL) is Labcorp test code 520130, billed with CPT 83516, 86038, 86235. Specimen: Serum. Turnaround time: 14 - 21 days. Performing laboratory: Labcorp, CLIA
34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
Test code520130
CPT83516; 86038; 86235(x7)
LOINC—
SpecimenSerum
Volume4 mL
Minimum volume3 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time14 - 21 days
Storage / transportRefrigerate.
Test includes
Anti-Nuclear Ab (ANA) by IFA; Anti-Scl 70 Ab; Anti-RNA Polymerase III Ab; Anti-Centromere Ab; Anti-Th/To Ab; Anti-U1 RNP Ab; Anti-U3 RNP (Fibrillarin) Ab; Anti-PM/Scl-100 Ab; Anti-Pm/Scl-75 Ab
Use
The new Scleroderma Comprehensive Plus Profile is the most comprehensive Scleroderma panel available on the market, and when combined with typical clinical features, can assist in the diagnosis and management of early or established disease. Identifying autoantibodies earlier in the disease can aid in diagnosis, prognosis and predicting the risk for end-stage organ complications, allowing for more aggressive intervention. In Scleroderma patients, anti-PM/Scl-75 and anti-PM/Scl-100 antibodies can be found in diffuse or limited cutaneous disease. The presence of both antibodies is highly associated with inflammatory Myositis.
Methodology
See individual test components.
Collection instructions
Separate serum from cells within one hour of collection. Transfer to a plastic transport tube before shipping.
Stability
| Temperature | Period |
|---|
| Room temperature | 7 days |
| Refrigerated | 14 days |
| Frozen | 60 days |
| Freeze/thaw cycles | Stable x1 |
Causes for rejection
Grossly hemolyzed; bacterial contamination; lipemic specimen; icteric specimen; non-serum specimen types
Limitations
This test was developed and its performance characteristics determined by LabCorp. It has not been cleared or approved by the Food and Drug Administration.
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 83516, 86038, 86235
- 21-Hydroxylase Autoantibodies, Serum
ARUP LaboratoriesTest code 3001962CPT 83516Serum Separator Tube (SST) or Plain Red.TAT 2-7 days
- Acetylcholine Receptor and Striated Muscle Antibodies Reflexive Panels, and Titin Antibody
Cleveland Clinic LaboratoriesTest code ACESTRCPT 83516, 86041, 86042, 86255SerumTAT 2 - 9 days
- Acetylcholine Receptor Antibodies and Striated Muscle Antibodies Reflexive Panels, and Titin Antibody
ARUP LaboratoriesTest code 2005639CPT 83516, 86041, 86042, 86043, 86255, 86256Plain red top or Serum Separator Tube (SST).TAT 1-8 days
- Adrenal 21-Hydroxylase Autoantibodies (Endocrine Sciences)
LabcorpTest code 504805CPT 83516SerumTAT 7 - 10 days
- ALLOGEN AutoAntibody
Cleveland Clinic LaboratoriesTest code TTAUTOCPT 83516Whole bloodTAT 15 days
- ANCA Profile (RDL)
LabcorpTest code 520149CPT 83516, 86036SerumTAT 7 - 10 days
- ANCA-Associated Vasculitis Profile (ANCA/MPO/PR3)
ARUP LaboratoriesTest code 3003745CPT 83516, 86036Serum separator tube.TAT 2-5 days
- Anti IgE
Cleveland Clinic LaboratoriesTest code ANTIGECPT 83516SerumTAT 6 - 8 days
- Anti-C1q Antibody, IgG
ARUP LaboratoriesTest code 2007601CPT 83516Serum separator tube.TAT 1-15 days
- Anti-C1q Antibody, IgG
Cleveland Clinic LaboratoriesTest code AC1QGGCPT 83516SerumTAT 2 - 16 days
- Anti-Carbamylated Protein (CarP) Antibody
LabcorpTest code 520311CPT 83516SerumTAT 7 - 10 days
- Anti-CEP-1 Ab, IgG (RDL)
LabcorpTest code 520133CPT 83516SerumTAT 7 - 10 days
- Anti-cN-1A (NT5c1A) IBM
Cleveland Clinic LaboratoriesTest code CN1AABCPT 83516SerumTAT 8 - 11 days
- Anti-cN-1A Ab (NT5c1A) IBM (RDL)
LabcorpTest code 520061CPT 83516SerumTAT 7 - 10 days
- Anti-Dense Fine Speckled Protein 70 kDa (DFS70) Ab
LabcorpTest code 520313CPT 83516SerumTAT 7 - 10 days
- Anti-EJ Ab (RDL)
LabcorpTest code 520026CPT 83516SerumTAT 14 - 21 days
- Anti-ENA6 Plus DFS70Ab Profile
LabcorpTest code 520301CPT 83516, 86235SerumTAT 14 - 21 days
- Anti-Fodrin Antibodies, IgG & IgA (RDL)
LabcorpTest code 520134CPT 83516SerumTAT 7 - 14 days
- Anti-Glomerular Basement Membrane Antibodies (RDL)
LabcorpTest code 520137CPT 83516SerumTAT 7 - 14 days
- Anti-GP-210 Ab (RDL)
LabcorpTest code 520139CPT 83516SerumTAT 7 - 14 days
- Anti-gp210 Antibody, IgG
ARUP LaboratoriesTest code 3002477CPT 83516Serum separator tube (SST).TAT 1-8 days
- Anti-HMGCR Ab
LabcorpTest code 520385CPT 83516SerumTAT Three times per week
- Anti-Ku Ab (RDL)
LabcorpTest code 520030CPT 83516SerumTAT 14 - 21 days
- Anti-MCV Antibody
LabcorpTest code 520375CPT 83516SerumTAT 10 days
- Anti-MDA-5 Ab (CADM-140) (RDL)
LabcorpTest code 520002CPT 83516SerumTAT 7 - 10 days
- Anti-Mi-2 Ab (RDL)
LabcorpTest code 520000CPT 83516SerumTAT 14 - 21 days
- Anti-MPO Ab (RDL)
LabcorpTest code 520297CPT 83516SerumTAT 3 - 5 days
- Anti-NXP-2 (P140) Ab (RDL)
LabcorpTest code 520004CPT 83516SerumTAT 7 - 10 days
- Anti-OJ Ab (RDL)
LabcorpTest code 520028CPT 83516SerumTAT 14 - 21 days
- Anti-Phospholipase A2 Receptor (PLA2R) Antibody, IgG by ELISA
ARUP LaboratoriesTest code 3016767CPT 83516Serum separator tube.TAT 1-7 days
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation