Anticardiolipin Antibodies (ACA), IgM, Quantitative: Labcorp test 161828

Labcorp test 161828, CPT 86147. Specimen: Serum. Turnaround: 2 - 4 days.

Anticardiolipin Antibodies (ACA), IgM, Quantitative is Labcorp test code 161828, billed with CPT 86147. Specimen: Serum. Turnaround time: 2 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code161828
CPT86147
LOINC3182-3
SpecimenSerum
Volume1 mL
Minimum volume0.5 mL
ContainerRed-top tube or gel-barrier tube
Turnaround time2 - 4 days
Storage / transportRoom temperature

Test includes

This test includes anticardiolipin antibodies, IgM, quantitative.

Use

Anticardiolipin IgM antibodies (aCL IgM) are one of the principal antiphospholipid antibodies (aPL) evaluated in the laboratory assessment of antiphospholipid syndrome (APS). Together with lupus anticoagulant (LA) and anti-β2-glycoprotein I (aβ2GPI) antibodies, aCL IgM forms part of the recommended first-line antibody panel for APS evaluation and classification.

Methodology

Thermo Fisher EliA™ automated FEIA-based autoantibody test

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x5
TemperaturePeriod
Room temperature7 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x5
TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x5

Causes for rejection

Hemolysis; lipemia; icteric specimen

Reference range

Anticardiolipin Antibodies (ACA), IgM: 0.0–29.4 MPL-U/mL

Limitations

Anticardiolipin IgM antibodies may be detected transiently during or following acute bacterial or viral infections, in individuals with syphilis and in association with certain medications or other inflammatory conditions. These transient antibodies are often of low titer and generally are not associated with the thrombotic or obstetric manifestations characteristic of APS. Low-level aCL IgM antibodies are relatively common in the general population and may occur in association with infections, medications, aging, pregnancy, other autoimmune disorders or malignancy. Therefore, APS should not be diagnosed on the basis of a single positive aCL IgM result. Antibody positivity should be…

LOINC map

Result codeResult nameUnitsResult LOINC
161830Anticardiolipin Ab,IgM,QnMPL-U/mL3182-3

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86147

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation