Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Immunoglobulin G, Subclass 2

Immunoglobulin G, Subclass 2: Labcorp test 160515

Labcorp test 160515, CPT 82787. Specimen: Serum. Turnaround: 3 - 5 days.

Immunoglobulin G, Subclass 2 is Labcorp test code 160515, billed with CPT 82787. Specimen: Serum. Turnaround time: 3 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code160515
CPT82787
LOINC2467-9
SpecimenSerum
Volume1 mL
Minimum volume0.4 mL
ContainerRed-top tube or gel-barrier tube
Turnaround time3 - 5 days
Storage / transportRoom temperature

Also known as: IgG Subclass 2; IgG 2

Use

Evaluate antipolysaccharide antibodies, sinopulmonary infections, immunodeficiency syndrome, and patients who demonstrate a poor response to carbohydrate antigens (group A strep, pneumococcus)

Methodology

Immunologic

Collection instructions

Transfer specimen to a plastic transport tube.

Stability

TemperaturePeriod
Room temperature13 days
Refrigerated13 days
Frozen13 days
Freeze/thaw cyclesStable x3

Causes for rejection

Gross lipemia; hemolysis

Reference range

See table. Immunoglobulin G, Subclass 2 Age Range (mg/dL) Cord 143−453 0 to 2 m 40−167 3 to 5 m 23−147 6 to 8 m 37−60 9 to 35 m 30−327 3 to 4 y 54−271 5 to 6 y 68−327 7 to 8 y 84−355 9 to 10 y 94−389 11 to 12 y 90−450 13 to 14 y 115−445 15 to 17 y 122−505 18 to 19 y 133−509 >19 y 130−555

Special instructions

State patient's age on the request form.

Limitations

This procedure is not suitable for the measurement of samples containing rheumatoid factor, paraproteins, other circulating immune complexes (CICs), or for lipemic or hemolyzed samples due to the unpredictable degree of nonspecific light scatter these sample types may generate. The results obtained from measuring IgG subclasses should not be used in assessing atopy in allergic patients.

LOINC map

Result codeResult nameUnitsResult LOINC
160515IgG, Subclass 2mg/dL2467-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82787

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation