Immunoglobulin A, Subclasses (1-2): Labcorp test 123049
Labcorp test 123049, CPT 82784, 82787. Specimen: Serum. Turnaround: 3 - 6 days.
Immunoglobulin A, Subclasses (1-2) is Labcorp test code 123049, billed with CPT 82784, 82787. Specimen: Serum. Turnaround time: 3 - 6 days. Performing laboratory: Labcorp, CLIA
34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Quest Diagnostics, Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Cleveland Clinic Laboratories.
Test code123049
CPT82784; 82787(x2)
LOINC2458-8, 6886-6, 6939-3
SpecimenSerum
Volume2 mL
Minimum volume1 mL
ContainerRed-top tube or gel-barrier tube
Turnaround time3 - 6 days
Storage / transportMaintain specimen at room temperature.
Also known as: IgA Subclasses; IgA 1,2
Test includes
Quantitation of IgA 1 , IgA 2 , total IgA
Use
Study IgA deficiencies in patients in association with recurrent sinopulmonary infections or repeated transfusions; study IgA elevations associated with IgA myeloma
Methodology
Immunologic
Collection instructions
Transfer specimen to a plastic transport tube.
Stability
| Temperature | Period |
|---|
| Room temperature | 14 days |
| Refrigerated | 14 days |
| Frozen | 14 days |
| Freeze/thaw cycles | Stable x3 |
Causes for rejection
Gross lipemia; hemolysis
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|
| Immunoglobulin A, Qn, Serum | mg/dL | | 2458-8 |
| IgA, Subclass 1 | mg/dL | | 6886-6 |
| IgA, Subclass 2 | mg/dL | | 6939-3 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 82784, 82787
- Autoimmune Cerebellar Ataxia Panel
Quest DiagnosticsTest code 90133CPT 82784, 86255, 86364, 865963 mL serum
- Celiac Antibodies Profile tTG IgA, tTG IgG, DGP IgA, DGP IgG, and Total IgA
LabcorpTest code 164010CPT 82784, 86258, 86364SerumTAT 2 - 5 days
- Celiac Antibodies Profile tTG IgA, tTG IgG, DGP IgA, DGP IgG, EMA IgA, and Total IgA
LabcorpTest code 165126CPT 82784, 86231, 86258, 86364SerumTAT 3 - 5 days
- Celiac Antibodies tTG IgA and Total IgA With Reflex to tTG IgG and DGP IgG
LabcorpTest code 164047CPT 82784, 86364SerumTAT 2 - 3 days
- Celiac Antibodies tTG IgA, DGP IgA, Total IgA With Reflex to tTG IgG and DGP IgG
LabcorpTest code 164002CPT 82784, 86258, 86364SerumTAT 2 - 4 days
- Celiac Antibodies tTG IgA, EMA IgA, Total IgA With Reflex to tTG IgG
LabcorpTest code 165142CPT 82784, 86231, 86364SerumTAT 3 - 6 days
- Celiac Disease Diagnosis Algorithm
Michigan Medicine Laboratories (MLabs)Test code CLIACCPT 827841.5 mL serumTAT 8 hours (initial IgA test); refer to ind
- Celiac Disease Reflexive Cascade, Serum
ARUP LaboratoriesTest code 3016817CPT 82784, 86231, 86258, 86364Serum separator tube (SST).TAT 2-6 days
- Celiac Screen with Reflex
Cleveland Clinic LaboratoriesTest code CELSCRCPT 82784, 86258, 86364SerumTAT 1 - 3 days
- Cryoglobulin Follow-up Monoclonal Gammopathy Evaluation
Michigan Medicine Laboratories (MLabs)Test code MGECRCPT 82784, 83883, 841652 mL serumTAT 72 hours
- Cryoglobulin, Qualitative , with Reflex to Quantitative IgA, IgG, and IgM
ARUP LaboratoriesTest code 2002063CPT 82595, 82784Plain red tube.TAT 3-5 days
- Cryoglobulin, Qualitative with Reflex to IFE Typing and Quantitative IgA, IgG, and IgM
ARUP LaboratoriesTest code 2002403CPT 82595, 82784, 86334Whole blood drawn in a prewarmed (37 degrees C) syringe. Specimen may be drawn dTAT 3-5 days
- Humoral Immunity Panel I
ARUP LaboratoriesTest code 0050980CPT 82784, 82787, 86317, 86581Serum separator tube.TAT 1-4 days
- IgA
Cleveland Clinic LaboratoriesTest code IGACPT 82784SerumTAT 1 - 4 days
- IgA, Immunoglobulin A (RDL)
LabcorpTest code 520072CPT 82784TAT 14 - 21 days
- IgG
Cleveland Clinic LaboratoriesTest code IGGCPT 82784SerumTAT 1 - 4 days
- IgG Index and Synthesis Rate
LabcorpTest code 203836CPT 82040, 82042, 82784Serum and cerebrospinal fluid (CSF)TAT 3 - 5 days
- IgG Subclasses
Cleveland Clinic LaboratoriesTest code IGGSUBCPT 82784, 82787SerumTAT 1 - 4 days
- IgG Synthesis, CSF (Tourtellotte and Index)
Cleveland Clinic LaboratoriesTest code TOURTCPT 82040, 82042, 82784Cerebrospinal fluid (CSF)TAT 1 - 4 days
- IgG, CSF
Cleveland Clinic LaboratoriesTest code CSFGCPT 82784Cerebrospinal fluid (CSF)TAT 1 - 4 days
- IgG, Immunoglobulin G (RDL)
LabcorpTest code 520108CPT 82784SerumTAT 4 - 6 days
- IgG,CSF / Albumin,CSF Ratio
Cleveland Clinic LaboratoriesTest code CGALBCPT 82042, 82784Cerebrospinal fluid (CSF)TAT 1 - 4 days
- IgM
Cleveland Clinic LaboratoriesTest code IGMCPT 82784SerumTAT 1 - 4 days
- Immunofixation (IFE), Serum
LabcorpTest code 001685CPT 82784, 86334SerumTAT 3 - 5 days
- Immunofixation (IFE), Serum and Protein Electrophoresis, Serum
LabcorpTest code 001495CPT 82784, 84155, 84165, 86334SerumTAT 3 - 5 days
- Immunofixation (IFE), Serum, Protein Electrophoresis (PE), Serum, and Quantitative Free κ and λ Light Chains (FLC) Plus Ratio, Serum
LabcorpTest code 120256CPT 82784, 83521, 84155, 84165, 86334SerumTAT 3 - 5 days
- Immunofixation, Daratumumab-Specific, Serum
LabcorpTest code 123218CPT 82784, 86334SerumTAT 6 - 8 days
- Immunofixation, Isatuximab-Specific, Serum
LabcorpTest code 123062CPT 82784, 86334SerumTAT 4 - 8 days
- Immunoglobulin A
ARUP LaboratoriesTest code 0050340CPT 82784Serum separator tube or green (sodium or lithium heparin).TAT 1-3 days
- Immunoglobulin A Quantitation
Michigan Medicine Laboratories (MLabs)Test code IGACPT 827840.5 mL serumTAT 8 hours
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation