Sexually Transmitted Infections (STI) Profile, With CT/NG/TV NAA (Women's Health): Labcorp test 144027
Labcorp test 144027, CPT 86592, 86704, 86706, 86803, 87340, 87389, 87491, 87591, 87661. Specimen: Serum and swab or urine. Turnaround: 1 - 4 days.
Also known as: Chlamydia; Gonorrhea; HBV; HCV; Hepatitis; HIV; STD; STI; Syphilis; Trichomonas
Test includes
RPR with reflex to quantitative RPR and confirmatory Treponema pallidum antibodies; HIV p24 Antigen/Antibody with reflex to confirmation; HBV screening and diagnosis (HBsAg, anti-HBs, HBc-total with reflex to IgM); HCV antibody with reflex to quantitative real-time PCR; Chlamydia trachomatis NAA , Neisseria gonorrhoeae NAA , and Trichomonas vaginalis NAA. If reflex testing is performed, additional charges/CPT code(s) may apply.
Use
This test is used to screen for and diagnose sexually transmitted infections and blood borne pathogens including syphilis, hepatitis B virus (HBV), hepatitis C virus (HCV), HIV, Chlamydia trachomatis, Neisseria gonorrhoeae and Trichomonas vaginalis. Testing aligns with current guidelines and recommendations.
Methodology
See individual test components.
Collection instructions
Serum specimen: Usual blood collection technique. Ct/GC: Option 1: Gen-Probe® Aptima® endocervical or vaginal swab. Endocervical swab: Remove excess mucus from the cervical os and surrounding mucosa using the cleaning swab (white-shaft swab in the package with red printing). Discard this swab. Insert the specimen collection swab (blue-shaft swab in the package with green printing) into the endocervical canal. Gently rotate the swab clockwise for 10 to 30 seconds in the endocervical canal to ensure adequate sampling. Withdraw the swab carefully; avoid contact with the vaginal mucosa. Remove the cap from the swab specimen transport tube and immediately place the specimen collection swab into the transport tube. Carefully break the swab shaft at the scoreline; use care to avoid splashing of the contents. Recap the swab specimen transport tube tightly. Vaginal Swab: Care Provider Specimen: Collect vaginal fluid sample using the Gen-Probe® Aptima® vaginal swab kit by contacting the swab to the lower third of the vaginal wall and rotating the swab for 10 to 30 seconds to absorb fluid. Immediately place the swab into the transport tube and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Patient Self-Collection: Partially open the package of the Gen-Probe® Aptima® vaginal swab kit. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new Aptima® swab specimen collection kit. Remove the swab. Carefully insert the swab into the vagina about two inches past the introitus and gently rotate the swab for 10 to 30 seconds, making sure the swab touches the walls of the vagina so that moisture is absorbed by the swab. Withdraw the swab without touching the skin. Immediately place the swab into the transport tube, and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Ct/GC: Option 2: Urine Specimen: The patient should not have urinated for at least one hour prior to specimen collection. Direct patient to provide a first-catch urine (approximately 20 to 30 mL of the initial urine stream) into a urine collection cup free of any preservatives. Collection of larger volumes of urine may result in specimen dilution that may reduce test sensitivity; lesser volumes may not adequately rinse organisms into the specimen. Female patients should not cleanse the labial area prior to providing the specimen. Add urine to the Aptima® Combo 2 urine collection device. The final volume must be between the two black lines on the device (about 2 mL).
Stability
Test Number Sample Type Room Temperature Refrigerated Frozen Freeze/thaw Cycles Serum 14 days 14 days 14 days Stable x3 Serum Antibody test: 24 hours PCR test: 24 hours Antibody test: 6 days PCR test: 72 hours Antibody test: 14 days PCR test: 6 weeks N/A N/A Serum 14 days 14 days 14 days Stable x3 Serum 48 hours 14 days 14 days Stable x5 Swab or urine Aptima® swab: 60 days Aptima® urine: 30 days Aptima® swab: 60 days Aptima® urine: 30 days N/A N/A
Causes for rejection
Hemolysis; lipemia; received outside of specimen and/or storage and/or labeling requirements; aliquot received for HIV testing; specimen in expired transport or incorrect transport device; specimens with inappropriate source for test requested; Aptima® urine transport >30 days from collection; Aptima® urine transport with incorrect specimen volume; Aptima® swab transport >60 days from collection; Aptima® swab specimen without a swab; cleaning swab (white-shaft swab) in Aptima® swab transport; Aptima® transport device with multiple swabs
Special instructions
This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample. If reflex test is performed, additional charges/CPT code(s) may apply. HIV p24 Antigen/Antibody With Reflex to Confirmation [083935] requires a dedicated, unopened, gel-barrier tube or red-top tube sent directly to the testing facility.
Limitations
Some of the assays in this panel have not been FDA cleared or approved for the screening of blood or plasma donors, nor have assay performance characteristics been established for immunocompromised or immunosuppressed patients, cord blood, or patients less than 2 years of age.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| STI Profile, CT/NG/TV | 006408 | Hep B Surface Ab, Qual | 22322-2 |
| STI Profile, CT/NG/TV | 006724 | HBV Interpretation | 95235-8 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 86592, 86704, 86706
- Intrauterine Fetal Demise/Stillborn Follow-up Profile
- Pregnancy, Initial Screening Profile
- Pregnancy, Initial Screening Profile With HBV Triple Panel
- Pregnancy, Initial Screening Profile With HBV Triple Panel, VZV Immunity and QuantiFERON®-TB Gold Plus
- PrEP Use Only: RPR With Reflex to Titer and Treponemal Antibodies
- Rapid Plasma Reagin (RPR) with Reflex to RPR Titer or T. pallidum Antibody by Particle Agglutination
- Rapid Plasma Reagin (RPR) with Reflex to Titer
- Rapid Plasma Reagin (RPR) with Reflex to Titer and FTA-ABS
- Rapid Plasma Reagin (RPR) with Reflex to Titer and TP-PA Confirmation
- RPR
- Sexually Transmitted Infections (STI) Profile
- Sexually Transmitted Infections (STI) Profile, With CT/NG NAA
- Sexually Transmitted Infections (STI) Profile, With CT/NG/TV NAA
- Syphilis monitoring for treatment, RPRM, serum
- Syphilis Neonatal evaluation only, with reflex titer
- Syphilis: RPR (Monitor) With Reflex to RPR Titer
- Syphilis: RPR With Reflex to RPR Titer and Treponemal Antibodies, Traditional Screening and Diagnosis Algorithm
- Syphilis: VDRL, CSF
- Treponema pallidum (VDRL), Cerebrospinal Fluid with Reflex to Titer
- Treponema pallidum (VDRL), Serum with Reflex to Titer
- VDRL, CSF
- XXX Sample Test Definition (for testing purposes only)
- Intrauterine Fetal Demise/Stillborn Follow-up Profile
- Pregnancy, Initial Screening Profile
- Sexually Transmitted Infections (STI) Profile
- Sexually Transmitted Infections (STI) Profile, With CT/NG NAA
- Syphilis: RPR With Reflex to RPR Titer and Treponemal Antibodies, Traditional Screening and Diagnosis Algorithm
- Bloodborne Pathogen Exposure Profile (HIV, HBV, HCV)
- HBV Baseline Evaluation, HCV Direct-acting Antivirals
- HBV Exposure Panel
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation