Labcorp test 143000, CPT 83880. Specimen: Serum. Turnaround: 1 - 2 days.

NT-proBNP is Labcorp test code 143000, billed with CPT 83880. Specimen: Serum. Turnaround time: 1 - 2 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code143000
CPT83880
LOINC33762-6
SpecimenSerum
Volume1 mL
Minimum volume0.7 mL ( Note: This volume does not allow for repeat testing.)
ContainerGel-barrier tube (preferred) or red-top tube
Turnaround time1 - 2 days
Storage / transportRoom temperature

Also known as: proBNP; Propeptide of Brain Natriuretic Peptide

Use

This assay is used as an aid in the diagnosis of individuals suspected of having congestive heart failure. The test is further indicated for the risk stratification of patients with acute coronary syndrome and congestive heart failure. The test may also serve as an aid in the assessment of increased risk of cardiovascular events and mortality in patients at risk for heart failure who have stable coronary artery disease.

Methodology

Electrochemiluminescence immunoassay (ECLIA)

Collection instructions

If a red-top tube is used, transfer separated serum to a plastic transport tube.

Stability

TemperaturePeriod
Room temperature3 days
Refrigerated6 days
Frozen24 months
Freeze/thaw cyclesStable x1

Causes for rejection

Citrate plasma specimen; grossly hemolyzed samples; improper labeling

Reference range

See table. Age Male (pg/mL) Female (pg/mL) 0 to 11 m Not established Not established 1 to 3 y 0−320 0−320 4 to 6 y 0−190 0−190 7 to 9 y 0−145 0−145 10 y 0−112 0−112 11 y 0−317 0−317 12 y 0−186 0−186 13 y 0−370 0−370 14 y 0−363 0−363 15 y 0−217 0−217 16 y 0−206 0−206 17 y 0−135 0−135 18 y 0−115 0−115 19 to 44 y 0−86 0−130 45 to 54 y 0−121 0−249 55 to 64 y 0−210 0−287 65 to 74 y 0−376 0−301 >74 y 0−486 0−738

Special instructions

This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.

Limitations

NT‑proBNP values should be assessed in conjunction with other cardiovascular risk factors and clinical findings. Interpreting results in the setting of comorbidities such as cardiac, pulmonary, and renal disease, which are likely to increase natriuretic peptides above current thresholds for HF, should be done with caution. The accuracy of natriuretic peptides for the detection of HF is reduced in the setting of atrial fibrillation and sepsis, and careful interpretation is warranted.

LOINC map

Result codeResult nameUnitsResult LOINC
143001NT-proBNPpg/mL33762-6

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83880

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation