Hereditary Angioedema (HAE): Labcorp test 123020
Labcorp test 123020, CPT 86160. Specimen: Serum, frozen and room temperature. Turnaround: 4 - 6 days.
Hereditary Angioedema (HAE) is Labcorp test code 123020, billed with CPT 86160. Specimen: Serum, frozen and room temperature. Turnaround time: 4 - 6 days. Performing laboratory: Labcorp, CLIA
34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), Quest Diagnostics, ARUP Laboratories, Cleveland Clinic Laboratories.
Test code123020
CPT86160(x2). If reflex testing is performed, concomitant CPT codes/charges will apply.
LOINC4477-6, 4498-2
SpecimenSerum, frozen and room temperature
VolumeThree aliquots: one tube 0.5 mL frozen , two tubes 1 mL each at room temperature
Minimum volumeThree aliquots: one tube 0.1 mL frozen , two tubes 0.5 mL each at room temperature
ContainerGel-barrier tube (preferred) or red-top tube. Note: Since specimen must be drawn on ice, plain red-top tubes will not clot as well as the use of clot-activated gel tubes.
Turnaround time4 - 6 days
Storage / transportFrozen sample should not be stored at room temperature (15°C to 30°C) for longer than six hours. Required room temperature samples are stable for three days, frozen samples for 14 days.
Also known as: Angioedema Profile; C 1 Esterase Inhibitor Deficiency Profile
Test includes
Complement C 4 , serum; complement C 1 esterase inhibitor, serum; and automatic reflex to complement C 1 esterase inhibitor, functional (at additional charge) if the C 1 esterase inhibitor result is ≥21 mg/dL.
Use
This test is used to aid clinicians in obtaining an appropriate diagnosis of hereditary angioedema (HAE). The profile begins with complement C 4 and complement C 1 esterase inhibitor with reflexing, if required, to complement C 1 esterase inhibitor, functional to distinguish HAE type I from type II. If the results are not consistent with HAE consider other types of angioedema and/or retesting during an acute attack.
Methodology
Immunologic
Collection instructions
Collect sample on ice. Separate serum from cells in a refrigerated centrifuge. If a refrigerated centrifuge is not available, chill centrifuge tube carriers before centrifuging. Transfer aliquots of serum to each of three plastic transport tubes. Freeze the required 0.5 mL frozen aliquot immediately at -20°C.
Causes for rejection
Plasma specimen; specimen not drawn on ice; stored specimen not frozen; gross bacterial contamination; excess lipemia; hemolysis; separate specimens not received (room temperature and frozen)
Limitations
Rheumatoid factors (>200 IU/mL) significantly increase the apparent C 4 concentration. This profile is not intended for the diagnoses of estrogen-dependent, estrogen-associated, drug-induced, or idiopathic angioedema. Also note that patients taking anabolic steroids may have falsely elevated C 4 values thus limiting the effectiveness of the profile's logic. Consider retesting the patient after discontinuation of anabolic steroids.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|
| 001833 | Complement C4, Serum | mg/dL | 4498-2 |
| 004649 | C1 Esterase Inhibitor, Serum | mg/dL | 4477-6 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 86160
- aHUS (complement-mediated TMA) Panel
Michigan Medicine Laboratories (MLabs)Test code MOAHUCPT 83516, 83520, 86160, 86161, 86162, 863343 mL serum AND 3 mL EDTA plasmaTAT 4 weeks
- ANA 12 Plus Profile, Do All (RDL)
LabcorpTest code 520175CPT 86038, 86147, 86160, 86200, 86225, 86235, 86376, 86431SerumTAT 14 - 21 days
- ANA 12 Profile, Do All (RDL)
LabcorpTest code 520299CPT 86038, 86147, 86160, 86225, 86235, 86376SerumTAT 14 - 21 days
- ANAlyzeR™ ANA, IFA with Reflex Titer/Pattern, Systemic Autoimmune Panel 1
Quest DiagnosticsTest code 36378CPT 83520, 86038, 86146, 86147, 86160, 86200, 86235, 86255, 863769 mL serum
- Angioedema Panel, Hereditary, Comprehensive
Quest DiagnosticsTest code 17706CPT 86160, 861613 mL frozen serum collected in a red-top tube (no gel)
- C-1-Esterase Inhibitor Panel
ARUP LaboratoriesTest code 0050139CPT 86160, 86161Serum separator tube.TAT 1-4 days
- C1 Esterase Inhibitor
Cleveland Clinic LaboratoriesTest code C1ESTCPT 86160SerumTAT 2 - 5 days
- C1-Esterase Inhibitor
ARUP LaboratoriesTest code 0050140CPT 86160Serum separator tube.TAT 1-4 days
- C1q Complement Antigen
Michigan Medicine Laboratories (MLabs)Test code C1QCPT 861601 ml serumTAT 3 - 6 days
- C1q Complement Protein
Cleveland Clinic LaboratoriesTest code COMC1QCPT 86160PlasmaTAT 6 - 11 days
- C3 Complement (RDL)
LabcorpTest code 520168CPT 86160SerumTAT 5 - 7 days
- C3 Complement, Antigen
Michigan Medicine Laboratories (MLabs)Test code C3CPT 861600.5 mL serumTAT 2 hours
- C3 Glomerulopathy Complement Panel
Michigan Medicine Laboratories (MLabs)Test code MOC3CCPT 83516, 83520, 86160, 86161, 86162, 863343 mL serum AND 3 mL EDTA plasmaTAT 4 weeks
- C3 Nephritic Factor
Cleveland Clinic LaboratoriesTest code C3NEPHCPT 86160SerumTAT 15 - 16 days
- C3a Level
Michigan Medicine Laboratories (MLabs)Test code FC3ARCPT 861602 mL EDTA plasmaTAT 21 - 45 days
- C4 Complement (RDL)
LabcorpTest code 520166CPT 86160SerumTAT 5 - 7 days
- C4 Complement, Antigen
Michigan Medicine Laboratories (MLabs)Test code C4CPT 861600.5 mL serumTAT 2 hours
- C4a Level
Michigan Medicine Laboratories (MLabs)Test code FC4ALCPT 861601.5 mL EDTA plasmaTAT 9 - 12 days
- C5 Complement, Antigen
Michigan Medicine Laboratories (MLabs)Test code C5CPCPT 861601 mL serumTAT 2 - 6 days
- C5 Inhibitors Drug Monitoring Panel
ARUP LaboratoriesTest code 3005961CPT 86160, 86161, 86162Plain red.TAT 1-9 days
- Complement C 3
Cleveland Clinic LaboratoriesTest code C3COMPCPT 86160PlasmaTAT 8 hours
- Complement C1 Esterase Inhibitor
LabcorpTest code 004648CPT 86160SerumTAT 3 - 4 days
- Complement C2
LabcorpTest code 161414CPT 86160SerumTAT 6 - 11 days
- Complement C3
LabcorpTest code 006452CPT 86160Serum (preferred) or plasmaTAT 1 - 2 days
- Complement C3a
LabcorpTest code 004220CPT 86160Plasma (EDTA) with Futhan, frozenTAT 4 - 7 days
- Complement C4
LabcorpTest code 001834CPT 86160Serum (preferred) or plasmaTAT 1 - 2 days
- Complement C4
Cleveland Clinic LaboratoriesTest code C4COMPCPT 86160PlasmaTAT 8 hours
- Complement C4a
LabcorpTest code 004330CPT 86160Plasma (EDTA) with Futhan, frozenTAT 4 - 7 days
- Complement Component 1Q Quantitative
ARUP LaboratoriesTest code 3021084CPT 86160Lavender (EDTA) or pink (K2EDTA).TAT 5-10 days
- Complement Component 3
ARUP LaboratoriesTest code 0050150CPT 86160Serum separator tube, Plasma separator tube, Green (Lithium heparin)TAT Within 24 hours
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation