Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Complement C4a

Complement C4a: Labcorp test 004330

Labcorp test 004330, CPT 86160. Specimen: Plasma (EDTA) with Futhan, frozen. Turnaround: 4 - 7 days.

Complement C4a is Labcorp test code 004330, billed with CPT 86160. Specimen: Plasma (EDTA) with Futhan, frozen. Turnaround time: 4 - 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), Quest Diagnostics, ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code004330
CPT86160
LOINC4501-3
SpecimenPlasma (EDTA) with Futhan, frozen
Volume1 mL
Minimum volume0.5 mL ( Note: This volume does not allow for repeat testing.)
ContainerLavender-top (EDTA) tube
Turnaround time4 - 7 days
Storage / transportFreeze

Also known as: Complement C 4 a des-Arginine

Use

Activation of the complement system plays an important role in our natural ability to ward off infection and in the pathogenesis of infection and inflammation. Anaphylatoxins produced as the result of complement activation play a role in a number of infectious and inflammatory conditions including sepsis, ischemia-reperfusion injury, immune complex diseases, and hypersensitivity diseases like asthma. Anaphylatoxins are also thought to be important in the pathogenesis of allergy, autoimmunity, neurodegenerative diseases, and cancer. Complement activation can occur through three separate mechanisms. The first mechanism to be discovered, referred to as the classical complement cascade, is…

Methodology

Radioimmunoassay (RIA)

Collection instructions

Collect EDTA whole blood sample into a chilled lavender-top tube. Immediately add Futhan preservative as directed in the Futhan collection kit (LabCorp N° 78946). Recap lavender tube and invert several times to mix well. Centrifuge the whole blood specimen to separate the plasma. Transfer the plasma into the plastic screw-cap tube that is included in the collection kit. The specimen must be submitted in this transfer tube, which is labeled with the words "Futhan Added." Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.

Stability

TemperaturePeriod
Room temperature6 hours
Refrigerated5 days
Frozen14 days
Freeze/thaw cyclesStable x1

Patient preparation

No radioactive isotopes administered within 48 hours prior to venipuncture.

Causes for rejection

No Futhan label added; non-Futhan label applied to tube; non-EDTA plasma; gross lipemia; gross hemolysis; turbid samples received

Reference range

Males: 152.0–1559.4 ng/mL Females: 215.7–2025.9 ng/mL

Special instructions

Futhan preservative must be added to samples immediately after collection. Collection kits containing this preservative are available as LabCorp N° 78946.

Limitations

Results for this test are for research purposes only by the assay's manufacturer. The performance characteristics of this product have not been established. Results should not be used as a diagnostic procedure without confirmation of the diagnosis by another medically established diagnostic product or procedure. Elevation of C 4 a levels is not predictive of any specific disease. Complement C 4 a levels can become increased in any condition associated with inflammation. Samples that are not properly collected and stored will produce erroneously elevated results due to in vitro activation. Blood must be drawn directly into tubes containing EDTA at a final concentration of at least 10 mM with…

LOINC map

Result codeResult nameUnitsResult LOINC
004331Complement C4ang/mL4501-3

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86160

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.