Glucose 6-Phosphate Dehydrogenase (G6PD), Quantitative and Hemoglobin, Cord Blood: Labcorp test 121074
Labcorp test 121074, CPT 82955, 85018. Specimen: Whole blood from umbilical cord. Turnaround: 2 - 4 days.
Also known as: G6PD, Quantitative, Blood and Hgb; G6PDH
Use
This test is used to evaluate glucose 6-phosphate dehydrogenase (G6PD) deficiency. G6PD deficiency, an X-linked disorder, is the most common enzymatic disorder of red blood cells in humans, affecting more than 400 million people worldwide. The clinical expression of G6PD variants encompasses a spectrum of hemolytic syndromes. Affected patients are most often asymptomatic, but many patients have episodic anemia, while a few have chronic hemolysis. With the most prevalent G6PD variants (G6PD A- and G6PD Mediterranean), hemolysis is induced in children and adults by the sudden destruction of older, more deficient erythrocytes after exposure to drugs having a high redox potential (including the…
Methodology
G6PD: Kinetic - 340 nm; Hemoglobin: Automated cell counter
Collection instructions
Collect whole blood from umbilical cord. Cord blood is especially susceptible to clotting. Testing will not be performed on clotted specimens. Please use Glucose 6-Phosphate Dehydrogenase (G6PD), Quantitative, Blood and Hemoglobin [121003] and submit peripheral whole blood instead of cord blood if clotting is problematic.
Causes for rejection
Hemoglobin: Hemolysis; tube not filled with minimum fill volume; specimen drawn in any anticoagulant other than EDTA; specimens diluted or contaminated with IV fluid; clotted specimen; improper labeling; transfer tubes with whole blood; lavender-top (EDTA) tubes received with plasma removed; samples more than 72 hours old G6PD: Frozen specimen
Reference range
See table. Age Male (units/g hemoglobin) Female (units/g hemoglobin) 0 to 6 days 10.0–20.0 Consistent with deficiency: <4.9 Consistent with borderline/ intermediate range: 4.9–9.9 10.0–20.0 Consistent with deficiency: <4.9 Consistent with borderline/ intermediate range: 4.9–9.9
Limitations
False normal results after hemolysis may occur (see Additional Information). Levels of G6PD are higher in the newborn than they are in the adult. When high levels are seen in older patients, it invariably reflects the presence of a young red blood cell population with reticulocytosis. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 005041 | Hemoglobin | g/dL | 718-7 |
| 121075 | G-6-PD, Quant | U/g Hb | 49502-8 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 82955, 85018
- G6PD Quantitative
- Glucose 6-Phosphate Dehydrogenase (G6PD), Quantitative, Blood and Hemoglobin
- Glucose 6-Phosphate Dehydrogenase (G6PD), Quantitative, Whole Blood and Red Blood Cell Count (RBC)
- Glucose-6-Phosphate Dehydrogenase
- Hereditary Hemolytic Anemia Cascade
- Hemoglobin
- Hemoglobin (Hb)
- Hemoglobin (Hb)
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation