Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Glucose 6-Phosphate Dehydrogenase (G6PD), Quantitative, Whole Blood and Red Blood Cell Count (RBC)

Glucose 6-Phosphate Dehydrogenase (G6PD), Quantitative, Whole Blood and Red Blood Cell Count (RBC): Labcorp test 001917

Labcorp test 001917, CPT 82955, 85041. Specimen: Whole blood. Turnaround: 2 - 4 days.

Glucose 6-Phosphate Dehydrogenase (G6PD), Quantitative, Whole Blood and Red Blood Cell Count (RBC) is Labcorp test code 001917, billed with CPT 82955, 85041. Specimen: Whole blood. Turnaround time: 2 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code001917
CPT82955; 85041
LOINC49502-8, 789-8
SpecimenWhole blood
Volume8 mL (4 mL in each of two tubes)
Minimum volumeRBC: two 500-μL lavender-top Microtainer™ tubes filled to at least 50% of tube capacity ( Note: If any other size lavender tube is used, the tube must be filled to at least 50% capacity of tube fill volume. Insufficient volume may limit the extent of procedures performed.); and G6PD: one lavender-top (EDTA) tube, green-top (heparin) tube or yellow-top (ACD) tube (0.1 mL) whole blood ( Note : This volume does not allow for repeat testing.)
ContainerTwo lavender-top (EDTA) tubes; or one green-top (heparin) tube and one lavender-top (EDTA) tube; or one yellow-top (ACD) tube and one lavender-top (EDTA) tube
Turnaround time2 - 4 days
Storage / transportRBC: Stable room temperature for 1 day or refrigerated for 72 hours. G6PD: Stable room temperature for 72 hours or refrigerated for seven days.

Also known as: G6PD, Quantitative, Blood and RBC

Test includes

G6PD, quantitative; red blood cell count (RBC)

Use

This test is used to evaluate glucose 6-phosphate dehydrogenase (G6PD) deficiency. G6PD deficiency, an X-linked disorder, is the most common enzymatic disorder of red blood cells in humans, affecting more than 400 million people worldwide. The clinical expression of G6PD variants encompasses a spectrum of hemolytic syndromes. Affected patients are most often asymptomatic, but many patients have episodic anemia, while a few have chronic hemolysis. With the most prevalent G6PD variants (G6PD A- and G6PD Mediterranean), hemolysis is induced in children and adults by the sudden destruction of older, more deficient erythrocytes after exposure to drugs having a high redox potential (including the…

Methodology

Kinetic − 340 nm

Causes for rejection

RBC: Hemolysis; tube not filled with minimum fill volume; specimen drawn in any anticoagulant other than EDTA; specimens diluted or contaminated with IV fluid; clotted specimen; improper labeling; transfer tubes with whole blood; lavender-top (EDTA) tubes received with plasma removed; samples more than 72 hours old. G6PD: Frozen specimen; clotted specimen.

Reference range

See table. Age Male (units/trillion RBCs) Female (units/trillion RBCs) 0 to 30 d 31 d to 6 m 7 m to 5 y 6 to 17 y 18 to 30 y >30 y

Limitations

False normal results after hemolysis may occur; vide infra. See Additional Information. Levels of G6PD are higher in the newborn than they are in the adult. When high levels are seen in older patients, it invariably reflects the presence of a young red blood cell population with reticulocytosis.

LOINC map

Result codeResult nameUnitsResult LOINC
005033RBCx10E6/uL789-8
001927G-6-PD, QuantU/10E12 RBC49502-8

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82955, 85041

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation