Sound Lab Consultants › National Lab Test Directory › Labcorp › Factor X, Chromogenic

Factor X, Chromogenic: Labcorp test 117904

Labcorp test 117904, CPT 85260. Specimen: Plasma, frozen. Turnaround: 2 - 3 days.

Factor X, Chromogenic is Labcorp test code 117904, billed with CPT 85260. Specimen: Plasma, frozen. Turnaround time: 2 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code117904
CPT85260
LOINC28657-5
SpecimenPlasma, frozen
Volume1 mL
ContainerBlue-top (sodium citrate) tube
Turnaround time2 - 3 days
Storage / transportFreeze.

Also known as: Stuart Factor; Stuart Prower Factor

Use

The chromogenic factor X activity test can be useful in monitoring patients on vitamin K antagonist therapy where baseline PT is prolonged.

Methodology

Factor X is activated by Russell viper venom which, in turn, hydrolyzes a chromogenic substrate to produce color.

Collection instructions

Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentifuge for 10 minutes. Use a second plastic pipette to remove plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when, please submit separate frozen specimens for each test requested . Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Stability

TemperaturePeriod
Frozen28 days
Freeze/thaw cyclesStable x3

Causes for rejection

Gross hemolysis; clotted specimen; frozen specimen thawed in transit; improper labeling

Reference range

• Nonanticoagulated subjects: 82% to 151% • Anticoagulant therapeutic range: 20% to 40% corresponds to an INR range of 2.0−3.0

Special instructions

If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.

Limitations

This assay should not be used for monitoring heparin or oral direct factor Xa inhibitors such as rivaroxaban (Xarelto), apixaban (Eliquis) or edoxaban (Savaysa).

LOINC map

Result codeResult nameUnitsResult LOINC
117908Factor X, Chromogenic%28657-5

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85260

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation