Factor X, Chromogenic: Labcorp test 117904
Labcorp test 117904, CPT 85260. Specimen: Plasma, frozen. Turnaround: 2 - 3 days.
Also known as: Stuart Factor; Stuart Prower Factor
Use
The chromogenic factor X activity test can be useful in monitoring patients on vitamin K antagonist therapy where baseline PT is prolonged.
Methodology
Factor X is activated by Russell viper venom which, in turn, hydrolyzes a chromogenic substrate to produce color.
Collection instructions
Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentifuge for 10 minutes. Use a second plastic pipette to remove plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when, please submit separate frozen specimens for each test requested . Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Stability
| Temperature | Period |
|---|---|
| Frozen | 28 days |
| Freeze/thaw cycles | Stable x3 |
Causes for rejection
Gross hemolysis; clotted specimen; frozen specimen thawed in transit; improper labeling
Reference range
• Nonanticoagulated subjects: 82% to 151% • Anticoagulant therapeutic range: 20% to 40% corresponds to an INR range of 2.0−3.0
Special instructions
If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.
Limitations
This assay should not be used for monitoring heparin or oral direct factor Xa inhibitors such as rivaroxaban (Xarelto), apixaban (Eliquis) or edoxaban (Savaysa).
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 117908 | Factor X, Chromogenic | % | 28657-5 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85260
- Bethesda Inhibitor
- Coagulation Factor 10 Activity, Chromogenic
- Coagulation Factor 10 Assay
- Extrinsic Pathway Coagulation Factor Profile
- Factor X Activity
- Factor X Activity With Inhibitor Reflex
- Factor X Assay
- Factor X, Activity
- Prolonged Clot Time Reflexive Profile
- Prolonged Protime Profile
- Coagulation Factor 10 Antigen
- Prolonged Protime Profile
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation