Factor X Assay: Cleveland Clinic Laboratories test FXC
Cleveland Clinic Laboratories test FXC, CPT 85260. Specimen: Plasma. Turnaround: 1 - 3 days.
Factor X Assay is Cleveland Clinic Laboratories test code FXC, billed with CPT 85260. Specimen: Plasma. Turnaround time: 1 - 3 days. Performing laboratory: Cleveland Clinic Laboratories, CLIA 36D0656094 (Cleveland, OH). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), Labcorp, ARUP Laboratories.
LaboratoryCleveland Clinic Laboratories
CLIA number36D0656094
Test codeFXC
CPT85260 - QTY (1)
LOINC3218-5
SpecimenPlasma
Volume2 mL
Minimum volume1 mL
ContainerSodium citrate (Lt. Blue)
Turnaround time1 - 3 days
Storage / transportFrozen
Methodology
Clotting Assay
Stability
| Temperature | Period |
|---|---|
| Ambient | 4 hours |
| Frozen | 14 days at -20 C; 6 months at -70 C |
| Refrigerated | Unacceptable |
Special instructions
Indicate previous prothrombin and partial thromboplastin time results on requisition.
Performed
Mon - Fri
Performing Laboratory
Cleveland Clinic Laboratories
View this test on Cleveland Clinic Laboratories's website → · Last checked 2026-11-29
Other tests billed with CPT 85260
- Bethesda Inhibitor
- Coagulation Factor 10 Activity, Chromogenic
- Coagulation Factor 10 Assay
- Extrinsic Pathway Coagulation Factor Profile
- Factor X Activity
- Factor X Activity With Inhibitor Reflex
- Factor X, Activity
- Factor X, Chromogenic
- Prolonged Clot Time Reflexive Profile
- Prolonged Protime Profile
- Coagulation Factor 10 Antigen
- Prolonged Protime Profile
Search the National Lab Test Directory · All Cleveland Clinic Laboratories tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation