Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Legionella species Culture

Legionella species Culture: Labcorp test 086868

Labcorp test 086868, CPT 87070. Specimen: Lung tissue, lung biopsy, transtracheal aspirate, pleural fluid, lung exudate, bronchial washing, bronchoalveolar lavage. Turnaround: 7 - 16 days.

Legionella species Culture is Labcorp test code 086868, billed with CPT 87070. Specimen: Lung tissue, lung biopsy, transtracheal aspirate, pleural fluid, lung exudate, bronchial washing, bronchoalveolar lavage (BAL), sputum. Turnaround time: 7 - 16 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code086868
CPT87070
LOINC88585-5
SpecimenLung tissue, lung biopsy, transtracheal aspirate, pleural fluid, lung exudate, bronchial washing, bronchoalveolar lavage (BAL), sputum
Volume1 mL lung exudate or 1 cc lung biopsy
ContainerSterile container
Turnaround time7 - 16 days
Storage / transportRefrigerate. Maintain specimens at 2°C to 8°C and transport to the laboratory within 24 hours of collection.

Also known as: Culture, Legionella sp

Test includes

This test includes a culture for Legionella spp; and isolation and identification if culture results warrant (additional charges/CPT code[s] may apply). CPT coding for microbiology and virology procedures often cannot be determined before the culture is performed.

Use

This test is used to isolate and identify Legionella sp.

Methodology

Culture on selective and nonselective media

Collection instructions

Contamination with normal flora from respiratory tract should be avoided. Transport to the laboratory within 24 hours of collection.

Causes for rejection

Swab specimen; inappropriate specimen transport device; improper labeling; specimen received after prolonged delay (usually more than 72 hours); specimen received in expired transport; environmental water samples such as air conditioning/cooling towers

Limitations

Sputum (expectorated), bronchial aspirates, and other specimens having normal flora are subject to bacterial overgrowth and are not as desirable as transtracheal aspirates, pleural fluid, and biopsy material for culture. Sensitivity of cultures is relatively low (50% to 80%); however, specificity is 100%. A direct fluorescent antibody smear without culture can be done to detect Legionella .

LOINC map

Result codeResult nameUnitsResult LOINC
086868Legionella Species Culture88585-5

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87070

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation