Labcorp test 008334, CPT 87070. Specimen: Swab of vaginal, endocervical, endometrial, urethral or prostatic secretions or discharge; semen. Turnaround: 3 - 5 days.

Genital Culture, Routine is Labcorp test code 008334, billed with CPT 87070. Specimen: Swab of vaginal, endocervical, endometrial, urethral or prostatic secretions or discharge; semen. Turnaround time: 3 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code008334
CPT87070
LOINC10352-3
SpecimenSwab of vaginal, endocervical, endometrial, urethral or prostatic secretions or discharge; semen
VolumeOne swab or 0.5 mL
ContainerOne swab in Amies agar gel bacterial swab transport; ESwab; sterile cup; bacterial culture transport swab with media
Turnaround time3 - 5 days
Storage / transportMaintain swab transport at room temperature. Do not refrigerate.

Also known as: Culture, Genital, Routine

Test includes

Culture; isolation, identification (additional charges/CPT code[s] may apply), and if culture results warrant, susceptibility testing (at an additional charge). CPT coding for microbiology and virology procedures often cannot be determined before the culture is performed. Requests with only a written order and no test number indicated will be processed according to Default Testing for Routine Microbiology .

Use

Isolate and identify potentially aerobic pathogenic organisms, including Gardnerella vaginalis and Neisseria gonorrhoeae; establish the diagnosis of gonorrhea in medicolegal cases

Methodology

Culture; MALDI-TOF and/or biochemicals for identification

Collection instructions

Female: Do not use lubricant on speculum. Cervical mucus should be removed first before inserting swab into endocervical canal, move swab from side to side allowing several seconds for absorption of organisms by the swab. Return swab to the transport tube and label. Male: Using small wire swab, gently scrape the anterior urethral mucosa, or use a swab to collect specimen of urethral discharge.

Causes for rejection

Inappropriate specimen transport device; unlabeled specimen or name discrepancy between specimen and request label; specimen received after prolonged delay (usually more than 72 hours); specimen received in expired transport

Special instructions

Specify specimen source and pertinent clinical information on the request form. Specimens from other sources, such as genital, stool, urine, upper and lower respiratory specimens, cannot be cultured under the aerobic bacterial culture test number. If specimens are incorrectly submitted with an order for aerobic bacterial culture, the laboratory will process the specimen for the test based on the source listed on the request form. The client will not be telephoned to approve this change, but the change will be indicated on the report. Check expiration date of transport; do not use expired devices.

Limitations

Does not include Trichomonas vaginalis, Chlamydia trachomatis, Ureaplasma urealyticum, Mobiluncus sp. , or yeast speciation. For antepartum screening at 36 to 37 weeks of gestation for maternal Group B Streptococcus colonization, use Group B Streptococcus Colonization Detection, NAA [188132] or Group B Streptococcus Colonization Detection, NAA With Reflex to Susceptibilities [188139] .

LOINC map

Result codeResult nameUnitsResult LOINC
008334Genital Culture, Routine10352-3

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87070

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation