Antithrombin (AT) Antigen (Immunologic): Labcorp test 015057
Labcorp test 015057, CPT 85301. Specimen: Plasma, frozen. Turnaround: 2 - 3 days.
Use
This test is used for confirmation and characterization of congenital AT deficiency.
Methodology
Automated (LIATEST) enzyme immunoassay (EIA)
Collection instructions
Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Stability
| Temperature | Period |
|---|---|
| Frozen | 28 days |
| Freeze/thaw cycles | Stable x3 |
Patient preparation
Do not draw from an arm with a heparin lock or heparinized catheter.
Causes for rejection
Severe hemolysis; improper labeling; clotted specimen; specimen diluted with IV fluids; samples thawed in transit; improper sample type; sample out of stability
Reference range
Antithrombin Antigen Age Range 0 to 3 d 25–66% 4 d to 6 m 35–120% >6 m 80–120%
Special instructions
If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.
Limitations
AT testing should not be performed on patients on heparin therapy because heparin decreases plasma AT levels. AT results for individuals on warfarin therapy should be interpreted with caution because warfarin can increase levels of AT of patients with heterozygous deficiency into the normal range.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 015057 | Antithrombin Antigen | % | 27812-7 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85301
- Antithrombin (AT) Deficiency Profile
- Antithrombin Panel
- Antithrombin, Antigen
- Antithrombin (AT) Deficiency Profile
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation