Labcorp test 001982, CPT 82103. Specimen: Serum (preferred) or plasma. Turnaround: 1 - 2 days.

α1-Antitrypsin is Labcorp test code 001982, billed with CPT 82103. Specimen: Serum (preferred) or plasma. Turnaround time: 1 - 2 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code001982
CPT82103
LOINC1825-9
SpecimenSerum (preferred) or plasma
Volume1 mL
Minimum volume0.3 mL ( Note : This volume does not allow for repeat testing.)
ContainerRed-top tube, gel-barrier tube, lavender-top (EDTA) tube, or green-top (heparin) tube
Turnaround time1 - 2 days
Storage / transportMaintain specimen at room temperature.

Also known as: Acute Phase Proteins; Alpha 1 -Protease Inhibitor

Use

Detection of hereditary decreases in the production of α 1 -antitrypsin (α 1 AT). Decreased or nearly absent levels of α 1 AT can be a factor in chronic obstructive lung disease and liver disease. An increased prevalence of non-MM phenotypes is found with cryptogenic cirrhosis and with CAH. Cirrhosis in a child should raise consideration of α 1 AT deficiency or Wilson's disease. Diagnosis of inflammatory states, if elevated (eg, rheumatoid arthritis, bacterial infection, vasculitis, neoplasia).

Methodology

Immunologic

Collection instructions

Separate serum or plasma from cells.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Patient preparation

Overnight fasting is preferred.

Causes for rejection

Chylous serum

Reference range

See table. Age Male mg/dL Female mg/dL 0 to 7 d 8 to 30 d 31 d to 5 y 6 to 12 y 13 to 40 y >40 y

Limitations

α 1 AT may be elevated into normal range in heterozygous deficient patients during concurrent infection, pregnancy, estrogen therapy, steroid therapy, cancer, and during postoperative periods. Homozygous deficient patients will not show such elevation. Normal α 1 AT levels may occur in patients with liver disease who are heterozygotes. In normals, pregnancy and contraceptive medication may elevate levels. Levels are normally low at birth but rise soon thereafter.

Contraindications

If CRP is positive, retest α 1 AT in 10 to 14 days.

LOINC map

Result codeResult nameUnitsResult LOINC
001982Alpha-1-Antitrypsin, Serummg/dL1825-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82103

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation