Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Alpha-1-Antitrypsin Clearance, Quantitative by ELISA, Timed Stool

Alpha-1-Antitrypsin Clearance, Quantitative by ELISA, Timed Stool: ARUP Laboratories test 2011043

ARUP Laboratories test 2011043, CPT 82103. Specimen: Stool: Entire 24-, 48-, or 72-hour stool collection. Refrigerate during collection. Provide patient a Timed Stool Collec. Turnaround: 1-3 days.

Alpha-1-Antitrypsin Clearance, Quantitative by ELISA, Timed Stool is ARUP Laboratories test code 2011043, billed with CPT 82103. Specimen: Stool: Entire 24-, 48-, or 72-hour stool collection. Refrigerate during collection. Provide patient a Timed Stool Collection Kit (ARUP suppl. Turnaround time: 1-3 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code2011043
CPT82103 x2
LOINC13363-7, 1825-9, 18271-7, 25303-9, 30078-0
SpecimenStool: Entire 24-, 48-, or 72-hour stool collection. Refrigerate during collection. Provide patient a Timed Stool Collection Kit (ARUP supply # 44192 ). Available online through eSupply using ARUP Connect™ or contact ARUP Client Services at (800) 522-2787. AND Serum: Serum separator tube (SST) or Plasma: Plasma separation tube (PST). Also acceptable: Lavender (EDTA) or pink (K 2 EDTA).
Turnaround time1-3 days
Storage / transportFrozen.

Methodology

Enzyme-Linked Immunosorbent Assay/Quantitative Immunoturbidimetry

Collection instructions

Stool: Refer to instructions in Stool Collection-Timed Specimens (24, 48, 72 Hours) under Specimen Handling at https://www.aruplab.com. Submit entire stool collection in an ARUP approved transport container(s) provided in kit using additional containers as needed for the full collection (available separately, ARUP supply # 28077 ). (Min: 5 g) Serum or Plasma: Collect blood during the stool collection time interval. Allow serum to clot completely at room temperature. Separate from cells ASAP or within 2 hours of collection. Transfer 0.5 mL to an ARUP Standard Transport Tube. (Min: 0.2 mL)

Stability

Stool: Ambient: 24 hours; Refrigerated: 7 days; Frozen: 3 months Serum or Plasma: Ambient: 1 week; Refrigerated: 3 months; Frozen: 3 months (avoid freeze/thaw cycles)

Causes for rejection

Stool: Specimens in media or preservatives. Serum or Plasma: Hemolyzed.

Reference range

Test Number Components Reference Interval Alpha-1-Antitrypsin 90-200 mg/dL Alpha-1-Antitrypsin Stool, ELISA 0.00-0.50 mg/g Alpha-1-Antitrypsin Stool-Clearance 1 - 49 mL/day

Performed

Mon, Wed, Fri

Compliance Category

Laboratory Developed Test (LDT)

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
0050001Alpha-1-Antitrypsin1825-9
2011042Alpha-1-Antitrypsin Stool, ELISA25303-9
2011044Alpha-1-Antitrypsin Stool, ELISA-Time13363-7
2011045Alpha-1-Antitrypsin Stool, ELISA-Weight30078-0
2011047Alpha-1-Antitrypsin Stool-Clearance18271-7

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 82103

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation