Triglycerides: Labcorp test 001172

Labcorp test 001172, CPT 84478. Specimen: Serum (preferred) or plasma. Turnaround: Within 1 day.

Triglycerides is Labcorp test code 001172, billed with CPT 84478. Specimen: Serum (preferred) or plasma. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code001172
CPT84478
LOINC2571-8
SpecimenSerum (preferred) or plasma
Volume1 mL
Minimum volume0.7 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube, gel-barrier tube, or green-top (lithium heparin) tube. Do not use oxalate, EDTA, or citrate plasma.
Turnaround timeWithin 1 day
Storage / transportMaintain specimen at room temperature.

Use

Evaluate turbid samples of blood, plasma, and serum; work up of chylomicronemia; evaluate hyperlipidemia; occasional cases of diabetes mellitus and/or pancreatitis are detected by hypertriglyceridemia. High levels may occur with hypothyroidism, nephrotic syndromes, carbohydrate-sensitive hypertriglyceridemia, glycogen storage disease, and in hyperlipoproteinemias type I, IIb, III, IV, and V. Some alcoholics have hypertriglyceridemia which disappears with abstinence. Extremely high triglyceride levels may occur with alcohol abuse. Triglyceride is needed for calculation of LDL-C (low-density lipoprotein cholesterol) concentration. Disturbances in triglyceride metabolism relate to diabetes and…

Methodology

Enzymatic

Collection instructions

Separate serum or plasma from cells within 45 minutes of collection.

Stability

TemperaturePeriod
Room temperature7 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Patient preparation

Patient should fast overnight (12 hours preferred; eight hours acceptable) preceding collection of specimen.

Causes for rejection

Specimen collected in a glycerinated tube; improper labeling

Reference range

• Normal: <150 mg/dL • Borderline-high: 150−199 mg/dL • High: 200−499 mg/dL • Very high: >500 mg/dL

Limitations

If triglyceride is >800 mg/dL, LDL cannot be calculated accurately by the NIH formula. Some women on estrogens and high estrogen oral contraceptives have an increase of triglyceride. Increases occur with pregnancy, similar to those with oral contraceptives. The most common cause of triglyceride increase is inadequate patient fasting. Hypertriglyceridemia is associated with use of thiazide diuretics and β-adrenergic blocking agents.

LOINC map

Result codeResult nameUnitsResult LOINC
001172Triglyceridesmg/dL2571-8

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 84478

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation