Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Triglycerides, Serum or Plasma

Triglycerides, Serum or Plasma: ARUP Laboratories test 0020040

ARUP Laboratories test 0020040, CPT 84478. Specimen: Plasma separator tube or serum separator tube.. Turnaround: Within 24 hours.

Triglycerides, Serum or Plasma is ARUP Laboratories test code 0020040, billed with CPT 84478. Specimen: Plasma separator tube or serum separator tube.. Turnaround time: Within 24 hours. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Labcorp, Cleveland Clinic Laboratories.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code0020040
CPT84478
LOINC2571-8
SpecimenPlasma separator tube or serum separator tube.
Turnaround timeWithin 24 hours
Storage / transportRefrigerated.

Also known as: Serum triglycerides; TG blood; Trig

Use

Use to assess cardiovascular disease risk and guide therapy.

Methodology

Quantitative Enzymatic Assay

Collection instructions

Allow specimen to clot completely at room temperature. Separate serum or plasma from cells ASAP or within 2 hours of collection. Transfer 1 mL serum or plasma to an ARUP Standard Transport Tube. (Min: 0.2 mL)

Stability

After separation from cells: Ambient: 48 hours; Refrigerated: 1 week; Frozen: 3 months

Patient preparation

Fasting specimen is preferred.

Causes for rejection

Body Fluid (refer to Triglycerides, Fluid, ARUP test code 0020713).Collection tubes with glycerol-lubricated stoppers.

Reference range

Test Number Components Reference Interval Triglycerides, Serum or Plasma Desirable: 149 mg/dL or less Boarderline: 150-199 mg/dL Higher Risk: 200-499 mg/dL

Performed

Sun-Sat

Compliance Category

FDA

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
0020040Triglycerides, Serum or Plasma2571-8

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 84478

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation