Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Cleveland Clinic Laboratories › Myelopathy, Autoimmune/Paraneoplastic Evaluation, Serum

Myelopathy, Autoimmune/Paraneoplastic Evaluation, Serum: Cleveland Clinic Laboratories test MLPTHY

Cleveland Clinic Laboratories test MLPTHY, CPT 86053, 86255, 86341, 86363. Specimen: Serum. Turnaround: 9 - 13 days.

Myelopathy, Autoimmune/Paraneoplastic Evaluation, Serum is Cleveland Clinic Laboratories test code MLPTHY, billed with CPT 86053, 86255, 86341, 86363. Specimen: Serum. Turnaround time: 9 - 13 days. Performing laboratory: Cleveland Clinic Laboratories, CLIA 36D0656094 (Cleveland, OH). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Quest Diagnostics, Labcorp.
LaboratoryCleveland Clinic Laboratories
CLIA number36D0656094
Test codeMLPTHY
CPT86341 - QTY (1); 86255 - QTY (15); 86053 - QTY (1); 86363 - QTY (1)
LOINC—
SpecimenSerum
Volume4 mL
Minimum volume2 mL
ContainerNo additive (Red)
Turnaround time9 - 13 days
Storage / transportRefrigerated

Test includes

Amphiphysin Ab, S; AGNA-1, S; ANNA-1, S; ANNA-2, S; ANNA-3, S; AP3B2 IFA, S; DPPX Ab CBA, S; GABA-B-R Ab CBA, S; GAD65 Ab Assay, S; mGluR1 Ab IFA, S; MOG FACS, S; Neurochondrin IFA, S; NMO/AQP4 FACS, S; PCA-1, S; PCA-2, S; Septin-7 IFA, S; TRIM46 Ab IFA, S; CRMP -5-IgG, S

Methodology

Cell Binding Assay (CBA); Flow Cytometry (FC); Immunoblot (IB); Indirect Immunofluorescence Assay (IFA); Radioimmunoassay (RIA); Western Blot (WB)

Stability

TemperaturePeriod
Refrigerated28 days
Frozen28 days
Ambient72 hours

Special instructions

Draw 2 tubes to ensure adequate serum volume. Specimen collection is recommended before initiation of immunosuppressant medication. This test should not be requested in patients who have recently received radioisotopes (refer to Special Information). Centrifuge and transfer serum to standard aliquot tube.

Performed

Sun - Sat

Alternate specimens

4 mL; Serum; SST (Gold); Refrigerated; Draw 2 tubes to ensure adequate serum volume. Specimen collection is recommended before initiation of immunosuppressant medication. This test should not be requested in patients who have recently received radioisotopes (refer to Special Information). Centrifuge and transfer serum to standard aliquot tube.

Performing Laboratory

Mayo Clinic Dpt of Lab Med & Pathology

View this test on Cleveland Clinic Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 86053, 86255, 86341

Search the National Lab Test Directory · All Cleveland Clinic Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation