Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Inositol 1,4,5-Trisphosphate Receptor Type 1 (ITPR1) Antibody, IgG by CBA-IFA With Reflex to Titer, Serum

Inositol 1,4,5-Trisphosphate Receptor Type 1 (ITPR1) Antibody, IgG by CBA-IFA With Reflex to Titer, Serum: ARUP Laboratories test 3006031

ARUP Laboratories test 3006031, CPT 86255, 86256. Specimen: Serum separator tube.. Turnaround: 1-8 days.

Inositol 1,4,5-Trisphosphate Receptor Type 1 (ITPR1) Antibody, IgG by CBA-IFA With Reflex to Titer, Serum is ARUP Laboratories test code 3006031, billed with CPT 86255, 86256. Specimen: Serum separator tube.. Turnaround time: 1-8 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Quest Diagnostics, Labcorp, Michigan Medicine Laboratories (MLabs).
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code3006031
CPT86255; if reflexed, add 86256
LOINC96466-8
SpecimenSerum separator tube.
Turnaround time1-8 days
Storage / transportRefrigerated.

Also known as: cerebellar ataxia; encephalitis; ITPR 1; movement disorder; myelopathy; neuropathy

Use

Aids in the diagnosis of autoimmune cerebellar ataxia, encephalitis, neuropathy, and myelopathy. May be used to monitor treatment response in individuals who are antibody positive. The presence of ITPR1 antibodies may be associated with cerebellar ataxia, encephalitis with seizures, peripheral neuropathy, and myelopathy. ITPR1 antibody disease may be paraneoplastic, but tumor type is variable (eg, breast, lung, and renal cancers).

Methodology

Semiquantitative Cell-Based Indirect Fluorescent Antibody

Collection instructions

Separate serum from cells within 2 hours of collection. Transfer 1 mL serum to an ARUP standard transport tube. (Min: 0.2 mL)

Stability

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 month (Three freeze/thaw cycles are acceptable)

Causes for rejection

CSF or plasma. Contaminated, grossly hemolyzed, icteric, or lipemic specimens.

Reference range

Less than 1:10

Performed

Wed

Compliance Category

Laboratory Developed Test (LDT)

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
3006032ITPR1 Ab IgG CBA-IFA Screen, Serum96466-8

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 86255, 86256

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.